{"created":"2023-05-15T14:59:06.941985+00:00","id":80206,"links":{},"metadata":{"_buckets":{"deposit":"3d572eb5-f05c-44a4-8295-5e0f8cf51201"},"_deposit":{"created_by":1,"id":"80206","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"80206"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00080206","sets":["1"]},"author_link":["878827","878829","878825","878828","878830","878823","878824","878826"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020-07","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"635","bibliographicVolumeNumber":"10","bibliographic_titles":[{"bibliographic_title":"Frontiers in Oncology"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Real-time monitoring of C-ion-induced annihilation gamma-rays was implemented using a Compton camera in a mouse model. An adult C57BL/6 mouse was anesthetized, and C-ion beams were directed into the abdomen at 1 × 109 particles/s for 20 s. The 511 keV annihilation gamma-rays, generated by the interaction between the irradiated C-ion beam and the target mouse, were detected using a silicon/cadmium telluride (Si/CdTe) Compton camera for 20 min immediately after irradiation. The irradiated site and the peak intensity position of 511 keV gamma emissions due to C-ion beam irradiation on a mouse were observed at the abdomen of the mouse by developing Compton images. Moreover, the positron emitter transport was observed by evaluating the range of gamma-ray emission after the C-ion beam irradiation on the mouse. Our data suggest that by confirming the peak intensity and beam range of C-ion RT with Si/CdTe-based Compton camera, it would be possible to reduce the intra-fractional and inter-fractional dose distribution degradation. Therefore, the results of this study would contribute to the future development of adaptive therapy with C-ion RT for humans.","subitem_description_type":"Abstract"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.3389/fonc.2020.00635","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.frontiersin.org/articles/10.3389/fonc.2020.00635/full","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2234-943X","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Shiba, Shintaro"}],"nameIdentifiers":[{"nameIdentifier":"878823","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kumar Parajuli, Raj"}],"nameIdentifiers":[{"nameIdentifier":"878824","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sakai, Makoto"}],"nameIdentifiers":[{"nameIdentifier":"878825","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Oike, Takahiro"}],"nameIdentifiers":[{"nameIdentifier":"878826","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ohno, Tatsuya"}],"nameIdentifiers":[{"nameIdentifier":"878827","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nakano, Takashi"}],"nameIdentifiers":[{"nameIdentifier":"878828","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Parajuli, Raj","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"878829","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nakano, Takashi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"878830","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Use of a Si/CdTe Compton Camera for In vivo Real-Time Monitoring of Annihilation Gamma Rays Generated by Carbon Ion Beam Irradiation","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Use of a Si/CdTe Compton Camera for In vivo Real-Time Monitoring of Annihilation Gamma Rays Generated by Carbon Ion Beam Irradiation"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2020-07-17"},"publish_date":"2020-07-17","publish_status":"0","recid":"80206","relation_version_is_last":true,"title":["Use of a Si/CdTe Compton Camera for In vivo Real-Time Monitoring of Annihilation Gamma Rays Generated by Carbon Ion Beam Irradiation"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:43:42.232093+00:00"}