{"created":"2023-05-15T14:59:01.662222+00:00","id":80084,"links":{},"metadata":{"_buckets":{"deposit":"e21f2649-5b34-4c4a-8463-6f77d0f7130d"},"_deposit":{"created_by":1,"id":"80084","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"80084"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00080084","sets":["10:28"]},"author_link":["872469","872467","872475","872472","872470","872474","872468","872473","872471"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2020-06-01","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"我々は、重イオンビームを用いて、水透過を抑制する低膨潤性の電気透析用陽イオン交換膜(CEM)の開発を行っている。本研究では、作製したCEMの含水率を室温の希塩酸中で測定し、膨潤性を評価した。電気透析セルの過電圧を決定づける膜抵抗が一定の下で含水率を比較すると、市販膜Nafionが18%であったのに対して、作製したCEMは7.5%であった。この値は、γ線グラフト重合法により得られたCEMの3分の2でもあることから、含水率の抑制、すなわち膨潤性の低下が確認できた。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"日本膜学会第42年会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"宮下, 太志"}],"nameIdentifiers":[{"nameIdentifier":"872467","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野村, 幹弘"}],"nameIdentifiers":[{"nameIdentifier":"872468","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"澤田, 真一"}],"nameIdentifiers":[{"nameIdentifier":"872469","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"越川, 博"}],"nameIdentifiers":[{"nameIdentifier":"872470","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"八巻, 徹也"}],"nameIdentifiers":[{"nameIdentifier":"872471","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Miyashita, Taishi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"872472","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sawada, Shinichi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"872473","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Koshikawa, Hiroshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"872474","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamaki, Tetsuya","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"872475","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"重イオンビームによる低膨潤イオン交換膜の開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"重イオンビームによる低膨潤イオン交換膜の開発"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2020-06-17"},"publish_date":"2020-06-17","publish_status":"0","recid":"80084","relation_version_is_last":true,"title":["重イオンビームによる低膨潤イオン交換膜の開発"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:50:34.125947+00:00"}