@article{oai:repo.qst.go.jp:00079974, author = {Frojd, Erik and George, Stuart and Kodaira, Satoshi and C., Lopez-Cuenca and Mozzanica, A. and Pinsky, Lawrence and Redford, S. and Schmitt, B. and Frojd, Erik and George, Stuart and Satoshi, Kodaira and Pinsky, Lawrence}, journal = {Journal of Instrumentation}, month = {May}, note = {Measurements of mixed radiation fields are challenging, partly due to the high demands on dynamic range and large energy depositions from for example heavy ions. We show that the JUNGFRAU detector developed for photon science at free electron lasers is capable of accurately measuring the energy deposition of four different ion species from He 230 MeV/A with an Linear Energy Transfer (LET) of 3 keV/um to Fe 290 MeV/A with an LET of 440 keV/um , even at 0 deg polar angle with a 320 um thick silicon sensor.}, title = {Measurement of charge deposition from heavy ions with the charge integrating JUNGFRAU detector}, volume = {15}, year = {2020} }