{"created":"2023-05-15T14:58:55.009751+00:00","id":79929,"links":{},"metadata":{"_buckets":{"deposit":"d481a196-03b8-4033-bb80-6680e7761d27"},"_deposit":{"created_by":1,"id":"79929","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"79929"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00079929","sets":["11"]},"author_link":["866543","866544","866546","866545"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"5","bibliographicPageEnd":"267","bibliographicPageStart":"263","bibliographicVolumeNumber":"62","bibliographic_titles":[{"bibliographic_title":"ATOMOΣ 日本原子力学会誌「アトモス」 "}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"福島第一原子力発電所の廃炉においては,世界でも例のない事故炉からの溶融燃料デブリ等の安全かつ円滑な取り出しが求められている.我々は,事故炉内の高放射線,水中等の過酷環境下において,炉内の燃料デブリ性状把握等サーベイランスが可能な遠隔分析を実現するために,レーザー光およびプラズマ発光を耐放射線性光ファイバーで長距離伝送するレーザー誘起ブレークダウン分光(LIBS)法を提案し,技術開発を進めている.本稿では,開発した可搬型光ファイバー伝送LIBS技術を利用して様々な環境下や試料を用いて遠隔迅速その場分析を実証した試験結果,およびセラミックマイクロチップレーザーを適用したLIBS技術の適用可能性の試みについて解説する.","subitem_description_type":"Abstract"}]},"item_10004_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1882-2606 NGEGAL 62(5)247?","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"大場, 弘則"}],"nameIdentifiers":[{"nameIdentifier":"866543","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"若井田, 育夫"}],"nameIdentifiers":[{"nameIdentifier":"866544","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"平等, 拓範"}],"nameIdentifiers":[{"nameIdentifier":"866545","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Oba, Hironori","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"866546","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"過酷環境下での遠隔レーザー分析技術","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"過酷環境下での遠隔レーザー分析技術"}]},"item_type_id":"10004","owner":"1","path":["11"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-10-30"},"publish_date":"2019-10-30","publish_status":"0","recid":"79929","relation_version_is_last":true,"title":["過酷環境下での遠隔レーザー分析技術"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:57:40.452972+00:00"}