@article{oai:repo.qst.go.jp:00079819, author = {Akagi, Tomoya and Bellan, L. and Bolzon, B. and Cara, P. and Carin, Y. and Chauvin, N. and Comunian, M. and Dzitko, H. and Fagotti, E. and Harrault, F. and Kasugai, Atsushi and Kondo, Keitaro and Sakamoto, Keishi and Sugimoto, Masayoshi and Akagi, Tomoya and Kasugai, Atsushi and Kondo, Keitaro and Sakamoto, Keishi and Sugimoto, Masayoshi}, issue = {2}, journal = {Review of Scientific Instruments}, month = {Feb}, note = {The Linear IFMIF (International Fusion Materials Irradiation Facility) Prototype Accelerator (LIPAc) is aiming at demonstrating the low energy section of a 40 MeV/125 mA IFMIF deuteron accelerator up to 9 MeV with a full beam current in cw operation. For such a high- power beam, the LIPAc injector is required to produce a 100 keV D+ beam with 140 mA and match it for injection into the Radio Frequency Quadrupole (RFQ) accelerator. The injector is designed by CEA-Saclay based on the high intensity light ion source (SILHI). In 2019, the commissioning of the RFQ to demonstrate the D+ beam acceleration at a low duty cycle (0.1%) was conducted. A nominal beam current of 125 mA D+ beam was accelerated up to 5 MeV through the RFQ successfully. The LIPAc injector fully satisfied the requirements for RFQ beam commissioning at the pulse mode.}, title = {Commissioning of high current H+/D+ ion beams for the prototype accelerator of the International Fusion Materials Irradiation Facility}, volume = {91}, year = {2020} }