{"created":"2023-05-15T14:58:40.783168+00:00","id":79609,"links":{},"metadata":{"_buckets":{"deposit":"a6929d89-2510-4c70-a0f3-4f3ed987d02c"},"_deposit":{"created_by":1,"id":"79609","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"79609"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00079609","sets":["1"]},"author_link":["923345","923347","923349","923350","923348","923346"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020-02","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"48","bibliographicPageStart":"45","bibliographicVolumeNumber":"29","bibliographic_titles":[{"bibliographic_title":"日本赤外線学会誌"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"世界で4億人を超える糖尿病患者は、1日4-5回、採血によって血糖値を測定しなければならず、痛みや精神的ストレス、さらに感染症の危険を伴うなどの多くの問題をかかえている.我々は従来の黒体放射に比べて10億倍も強い尖塔出力を有する中赤外レーザー光の発生に成功した。このレーザーを用いて手のひらサイズの非侵襲血糖値センサーを開発し、採血型血糖値センサーとの比較検証を行ったところ、複数の健常者に対して臨床に求められる測定精度を満たすことを確認した.","subitem_description_type":"Abstract"}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0916-7900","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"山川, 考一"}],"nameIdentifiers":[{"nameIdentifier":"923345","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"赤羽, 温"}],"nameIdentifiers":[{"nameIdentifier":"923346","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"青山, 誠"}],"nameIdentifiers":[{"nameIdentifier":"923347","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Koichi, Yamakawa","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"923348","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yutaka, Akahane","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"923349","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Makoto, Aoyama","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"923350","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"中赤外レーザーを用いた採血不要の血糖値センサー","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"中赤外レーザーを用いた採血不要の血糖値センサー"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2020-03-23"},"publish_date":"2020-03-23","publish_status":"0","recid":"79609","relation_version_is_last":true,"title":["中赤外レーザーを用いた採血不要の血糖値センサー"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:49:10.441245+00:00"}