{"created":"2023-05-15T14:58:21.415722+00:00","id":79160,"links":{},"metadata":{"_buckets":{"deposit":"1194048f-8f6c-4a80-8964-2f8b6d4f5280"},"_deposit":{"created_by":1,"id":"79160","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"79160"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00079160","sets":["1"]},"author_link":["999518","999519","999520","999513","999516","999515","999514","999517","999522","999521"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageStart":"e1059","bibliographicVolumeNumber":"2","bibliographic_titles":[{"bibliographic_title":"JOR spine"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Manganese-enhanced magnetic resonance imaging (MEMRI) enables tract tracing to follow neural pathways through axonal transport. However, the method is problematic because of the high local concentrations of Mn involved. We developed a tetrananogel containing a dextran-manganese complex (Dex-Mn-Gel) and applied this nanogel to rats. MnCl (n = 5), Dex-Mn-Gel (n = 5), or saline control (n = 3) was injected into the left knee joint of the rats (n = 13). Inflammation and tissue alterations in the knee joint were also evaluated histologically. T1-weighted images were obtained on a 7 T MRI system 24 hours after the administration and compared across groups. The sciatic nerve in both legs and the surrounding musculature were used as regions of interest (ROI). No swelling was found in the knee joint infused with Dex-Mn-Gel, although prominent swelling of the knee joint was observed with MnCl. White blood cells inside the knee joint tissue infused with the Dex-Mn-Gel were significantly less abundant (45%,  < .05) compared with the knee joints infused with MnCl. Visualization of the sciatic nerve was significantly enhanced in rats treated with both forms of Mn compared with controls ( < .01). This study is the first to attempt intra-articular administration of a manganese contrast agent into joint-capsule and demonstrate tract visualization. The Dex-Mn-Gel can be taken up by the nerve endings and reduce Mn toxicity. Dex-Mn-Gel will provide a minimally invasive method for visualizing nerve tracts in vivo.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Wiley"}]},"item_8_relation_13":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"31463469","subitem_relation_type_select":"PMID"}}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1002/jsp2.1059","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://onlinelibrary.wiley.com/doi/full/10.1002/jsp2.1059","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2572-1143","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Eguchi, Yawara"}],"nameIdentifiers":[{"nameIdentifier":"999513","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Murayama, Shuhei"}],"nameIdentifiers":[{"nameIdentifier":"999514","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanamoto, Hirohito"}],"nameIdentifiers":[{"nameIdentifier":"999515","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Abe, Koki"}],"nameIdentifiers":[{"nameIdentifier":"999516","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Miyagi, Masayuki"}],"nameIdentifiers":[{"nameIdentifier":"999517","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takahashi, Kazuhisa"}],"nameIdentifiers":[{"nameIdentifier":"999518","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ohtori, Seiji"}],"nameIdentifiers":[{"nameIdentifier":"999519","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Aoki, Ichio"}],"nameIdentifiers":[{"nameIdentifier":"999520","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yawara, Eguchi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"999521","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ichio, Aoki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"999522","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Minimally invasive manganese-enhanced magnetic resonance imaging for the sciatic nerve tract tracing used intra-articularly administrated dextran-manganese encapsulated nanogels.","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Minimally invasive manganese-enhanced magnetic resonance imaging for the sciatic nerve tract tracing used intra-articularly administrated dextran-manganese encapsulated nanogels."}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2020-03-03"},"publish_date":"2020-03-03","publish_status":"0","recid":"79160","relation_version_is_last":true,"title":["Minimally invasive manganese-enhanced magnetic resonance imaging for the sciatic nerve tract tracing used intra-articularly administrated dextran-manganese encapsulated nanogels."],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:44:51.092444+00:00"}