{"created":"2023-05-15T14:58:12.860928+00:00","id":78966,"links":{},"metadata":{"_buckets":{"deposit":"ac2637bb-0822-41c7-8667-55585af4de7d"},"_deposit":{"created_by":1,"id":"78966","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"78966"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00078966","sets":["11"]},"author_link":["841543","841544","841542"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020-04","bibliographicIssueDateType":"Issued"},"bibliographic_titles":[{"bibliographic_title":"放射線化学会誌"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"High-dose radiation is used for sterilization of medical equipment and food irradiation. For these purposes, dose control is very important because quality of irradiated products depends on the absorbed dose. National Institute of Advanced Industrial Science and Technology is developing the high-dose standard using an alanine dosimeter. The alanine dosimeter can determine the dose by quantifying the amount of radiation induced radicals using an electron spin resonance (ESR) spectrometer. This article introduces the outline of ESR measurement required to establish the high-dose dosimetry.","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"山口英俊(産業技術総合研究所)"}],"nameIdentifiers":[{"nameIdentifier":"841542","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"清藤, 一"}],"nameIdentifiers":[{"nameIdentifier":"841543","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Seito, Hajime","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"841544","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"アラニン線量計を用いた大線量標準の開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"アラニン線量計を用いた大線量標準の開発"}]},"item_type_id":"10004","owner":"1","path":["11"],"pubdate":{"attribute_name":"公開日","attribute_value":"2020-02-13"},"publish_date":"2020-02-13","publish_status":"0","recid":"78966","relation_version_is_last":true,"title":["アラニン線量計を用いた大線量標準の開発"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:43:23.415548+00:00"}