{"created":"2023-05-15T14:57:04.288727+00:00","id":77444,"links":{},"metadata":{"_buckets":{"deposit":"18a503f6-8bc1-4b61-9008-74c5b67eb8c5"},"_deposit":{"created_by":1,"id":"77444","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"77444"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00077444","sets":["10:28"]},"author_link":["806311","806310","806313","806319","806320","806318","806317","806322","806316","806314","806312","806323","806309","806321","806308","806315"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2019-11-21","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"【目的】QST病院では、画像誘導炭素線治療として、Patient Handling System (PTH)を用いて、治療が行われている。本研究では、このPTHについて紹介し、定期的に実施しているQAの1年間の結果について報告する。【方法】PTHは、患者支援システム(固定具、ロボットアーム治療台)、患者セットアップ用X線システム 、レーザー等からなり、主に患者の画像の取得、幾何学的精度の維持、運動管理、および治療過程全体のサポート機能を有する位置照合用システムである。このPTHに関するQAでは、照射室レーザー、直交X線イメージングシステムやロボットアーム治療台の位置精度を確認する。今回、2018年4月から2019年3月までのQA結果(測定誤差)について解析した。【結果】 垂直と水平のレーザー位置精度については、最大±0.5mmと+0.5mmであった。位置照合装置の位置精度は、垂直X線管球のY方向は最大-0.1 mm、水平X線管球のZとY方向は、最大±0.1と-0.4 mm、回転系は最大+0.1degであった。垂直FPDのXとY方向は最大±0.1mmと最大+0.1mm、水平FPDのZとY方向は最大±0.1mmであった。位置照合装置と炭素線照射装置の両座標系の整合性に関しては、XとY方向は最大±0.3mm、Z方向は最大-0.4 mm、回転系は最大±0.1deg、アイソセンター位置精度の最大標準偏差は0.5 mm未満であった。【結語】 画像誘導炭素線治療として治療に用いられているPTHに関するQA結果を評価し、PTHに関する高精度な位置精度を確認できた。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"日本放射線腫瘍学会 第32回学術大会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"山岡, 恵士"}],"nameIdentifiers":[{"nameIdentifier":"806308","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"伊達, 美聡"}],"nameIdentifiers":[{"nameIdentifier":"806309","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"勝間田, 匡"}],"nameIdentifiers":[{"nameIdentifier":"806310","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山本, 淳史"}],"nameIdentifiers":[{"nameIdentifier":"806311","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"菅, 満喜人"}],"nameIdentifiers":[{"nameIdentifier":"806312","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"谷本, 克之"}],"nameIdentifiers":[{"nameIdentifier":"806313","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"河野, 良介"}],"nameIdentifiers":[{"nameIdentifier":"806314","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"辻, 比呂志"}],"nameIdentifiers":[{"nameIdentifier":"806315","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamaoka, Keisi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"806316","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Date, Mitsutoshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"806317","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Katsumata, Masashi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"806318","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamamoto, Atsushi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"806319","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Suga, Makito","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"806320","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tanimoto, Katsuyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"806321","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kohno, Ryosuke","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"806322","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tsuji, Hiroshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"806323","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"画像誘導炭素線治療におけるPatient Handling Systemに対する位置決めQA","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"画像誘導炭素線治療におけるPatient Handling Systemに対する位置決めQA"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-11-15"},"publish_date":"2019-11-15","publish_status":"0","recid":"77444","relation_version_is_last":true,"title":["画像誘導炭素線治療におけるPatient Handling Systemに対する位置決めQA"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:39:23.564248+00:00"}