{"created":"2023-05-15T14:56:53.047157+00:00","id":77201,"links":{},"metadata":{"_buckets":{"deposit":"efd2519d-c87b-461e-95d3-1c7875f97fde"},"_deposit":{"created_by":1,"id":"77201","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"77201"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00077201","sets":["1"]},"author_link":["999334","999335","999333","999336"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-07","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"2771","bibliographicPageStart":"2765","bibliographicVolumeNumber":"146","bibliographic_titles":[{"bibliographic_title":"Fusion Engineering and Design "}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"ITERブランケット遠隔保守装置のダスト除染試験を実施した。試験では、遠隔保守装置に使用される構造材(SUS329J4L)の試験片上に3種類の表面粗さ(Ra 12.5, Ra 6.3, Ra 1.6)を再現した。試験片上にはダストを模擬したタングステン粉末をのせ、除染にはナイロンブラシとSUS304ブラシを使用した。SUS304ブラシを使用した場合、表面粗さに関係なく約99%のダストを除去することができた。この結果から、除染に適した除染法や構造材条件について報告する。","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Elsevier"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1016/j.fusengdes.2019.05.028","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.sciencedirect.com/science/article/pii/S0920379619306672","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0920-3796","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"齋藤, 真貴子"}],"nameIdentifiers":[{"nameIdentifier":"999333","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"武田, 信和"}],"nameIdentifiers":[{"nameIdentifier":"999334","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Makiko, Saito","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"999335","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nobukazu, Takeda","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"999336","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Decontamination tests of dust under load for the ITER Blanket Remote Handling System","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Decontamination tests of dust under load for the ITER Blanket Remote Handling System"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-04-22"},"publish_date":"2019-04-22","publish_status":"0","recid":"77201","relation_version_is_last":true,"title":["Decontamination tests of dust under load for the ITER Blanket Remote Handling System"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:45:24.672124+00:00"}