{"created":"2023-05-15T14:56:52.736388+00:00","id":77194,"links":{},"metadata":{"_buckets":{"deposit":"d8ad99dd-9767-448e-a5cf-6da9394984b5"},"_deposit":{"created_by":1,"id":"77194","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"77194"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00077194","sets":["1"]},"author_link":["1001884","1001886","1001883","1001885"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"10","bibliographicPageEnd":"1204","bibliographicPageStart":"1200","bibliographicVolumeNumber":"75","bibliographic_titles":[{"bibliographic_title":"Radiological physics and technology"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"粒子線の品質管理(Quality Assurance: QA)の多くは光子線治療のそれと類似しているが、大きく異なる点は、深さ方向の評価である。ここでは、紙面の都合上、粒子線治療のQAについて、線量系、幾何学系、画像系、呼吸同期系、そして安全装置系の項目に分類し、その中から項目を絞って紹介する。関連学会から「粒子線治療装置の物理・技術的QAシステムガイドライン」やAAPM TG224 が出版されおり、また、陽子線と炭素線のQAに関する論文も出版されているので参照していただきたい。粒子線物理の基本的な内容はICRU78に明確にまとめられている。その他、各施設で独自に行っているQA項目については、ここでは述べない。","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":" "}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.6009/jjrt.2019_JSRT_75.10.1200","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/article/jjrt/75/10/75_2019_JSRT_75.10.1200/_article/-char/ja/","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":" 0369-4305","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"森, 慎一郎"}],"nameIdentifiers":[{"nameIdentifier":"1001883","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"河野, 良介"}],"nameIdentifiers":[{"nameIdentifier":"1001884","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shinichiro, Mori","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1001885","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ryosuke, Kohno","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1001886","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"粒子線、重粒子線装置の品質管理","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"粒子線、重粒子線装置の品質管理"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-10-23"},"publish_date":"2019-10-23","publish_status":"0","recid":"77194","relation_version_is_last":true,"title":["粒子線、重粒子線装置の品質管理"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:36:08.143617+00:00"}