{"created":"2023-05-15T14:56:28.897764+00:00","id":76690,"links":{},"metadata":{"_buckets":{"deposit":"ff0e8e2a-633e-4c5d-a934-6b8a027f29c9"},"_deposit":{"created_by":1,"id":"76690","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"76690"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00076690","sets":["10:28"]},"author_link":["781638","781636","781641","781639","781637","781640"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2019-09-07","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"本研究では、BNCT薬物動態評価のための新規B-10定量分析法の開発を目指している。提案手法では、従来の即発ガンマ線分析とは異なり、中性子捕獲反応で発生するα粒子を検出することでB-10を定量しようとする。高エネルギーα線検出器として張力準安定流体検出器(TMFD)を用いる。TMFDはガンマ線や閾エネルギー以下の中性子に不感であるためバックグラウンドが低く、従来分析法よりも遙かに低強度の中性子源でも実用的な10B定量分析システムを構成できる可能性がある。発表では、原理実証実験の結果を報告する。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第16回日本中性子捕捉療法学会学術大会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Bakr, Mahmoud"}],"nameIdentifiers":[{"nameIdentifier":"781636","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Masuda, Kai"}],"nameIdentifiers":[{"nameIdentifier":"781637","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sera, Satoru"}],"nameIdentifiers":[{"nameIdentifier":"781638","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takahashi, Yoshiyuki"}],"nameIdentifiers":[{"nameIdentifier":"781639","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Konishi, Satoshi"}],"nameIdentifiers":[{"nameIdentifier":"781640","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Masuda, Kai","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"781641","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"An Alternative method of B-10 Quantitative Analysis for BNCT based on a Compact Neutron Source and a-Particles Detector","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"An Alternative method of B-10 Quantitative Analysis for BNCT based on a Compact Neutron Source and a-Particles Detector"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-09-09"},"publish_date":"2019-09-09","publish_status":"0","recid":"76690","relation_version_is_last":true,"title":["An Alternative method of B-10 Quantitative Analysis for BNCT based on a Compact Neutron Source and a-Particles Detector"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:15:02.851697+00:00"}