{"created":"2023-05-15T14:56:13.785305+00:00","id":76369,"links":{},"metadata":{"_buckets":{"deposit":"81ae4972-ebfe-4af0-80c4-8d15b1faf5da"},"_deposit":{"created_by":1,"id":"76369","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"76369"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00076369","sets":["1"]},"author_link":["825965","825966","825969","825972","825967","825971","825964","825970","825968","825973"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-07","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"100414","bibliographicVolumeNumber":"12","bibliographic_titles":[{"bibliographic_title":"Perspectives in Science"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In this study, a portable radioactive plume monitor using a silicon photodiode was developed for the detection of a radioactive plume (e.g.131I,134Cs and137Cs) in an emergency situation. It was found that the background count rate was proportional to ambient dose equivalent rate and the detection limit for the monitor at 20 Sv h−1 as an ambient dose equivalent rate was evaluated to be 187 Bq m−3 using the ISO11929 method. These results suggest that the detection limit for the system can be decreased effectively by lead shielding with optimized thickness.","subitem_description_type":"Abstract"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1016/j.pisc.2019.100414","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.sciencedirect.com/science/article/pii/S2213020919300217","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2213-0209","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Tamakuma, Yuki"}],"nameIdentifiers":[{"nameIdentifier":"825964","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamada, Ryohei"}],"nameIdentifiers":[{"nameIdentifier":"825965","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Iwaoka, Kazuki"}],"nameIdentifiers":[{"nameIdentifier":"825966","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hosoda, Masahiro"}],"nameIdentifiers":[{"nameIdentifier":"825967","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kuroki, Tomohiro"}],"nameIdentifiers":[{"nameIdentifier":"825968","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mizuno, Hiroyuki"}],"nameIdentifiers":[{"nameIdentifier":"825969","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamada, Koji"}],"nameIdentifiers":[{"nameIdentifier":"825970","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Furukawa, Masahide"}],"nameIdentifiers":[{"nameIdentifier":"825971","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tokonami, Shinji"}],"nameIdentifiers":[{"nameIdentifier":"825972","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Iwaoka, Kazuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"825973","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"A portable radioactive plume monitor using a silicon photodiode","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"A portable radioactive plume monitor using a silicon photodiode"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-07-29"},"publish_date":"2019-07-29","publish_status":"0","recid":"76369","relation_version_is_last":true,"title":["A portable radioactive plume monitor using a silicon photodiode"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:10:21.623176+00:00"}