{"created":"2023-05-15T14:55:56.943043+00:00","id":75976,"links":{},"metadata":{"_buckets":{"deposit":"ad944099-a1d7-4475-91d8-c3c32557a83f"},"_deposit":{"created_by":1,"id":"75976","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"75976"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00075976","sets":["11"]},"author_link":["763781","763784","763780","763779","763783","763785","763777","763778","763782"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"146","bibliographicPageEnd":"29","bibliographicPageStart":"28","bibliographic_titles":[{"bibliographic_title":"放射線と産業"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"海水と河川水から電気を生産する逆電気透析(Reverse Electrodialysis, RED)発電は、発電出力の安定性や環境負荷の低さなどから注目されている。REDの発電性能は、カチオン交換膜(CEM)とアニオン交換膜(AEM)の特性に依存する。そこで本研究では、放射線グラフト重合法でCEMとAEMを作製し、RED発電試験を行った。フッ素樹脂基材膜へのガンマ線照射後、スチレンのグラフトとスルホン化でCEM、クロロメチルスチレンのグラフトと四級化でAEMを作製した。作製したCEMとAEMの抵抗は、それぞれ0.27、0.40 Ω cm2であり、現行のCEM(2.7 Ω cm2)とAEM(2.4 Ω cm2)の抵抗よりも遥かに低かった。RED発電試験では、放射線グラフトCEM、AEMを用いたとき、最大出力は0.39 W/m2に達した。これは現行膜を用いた場合の最大出力の1.3倍であり、低抵抗膜の使用による発電出力の向上を実証できた。","subitem_description_type":"Abstract"}]},"item_10004_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"一般財団法人 放射線利用振興協会"}]},"item_10004_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0286-8873","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"澤田, 真一"}],"nameIdentifiers":[{"nameIdentifier":"763777","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"安保, 貴和"}],"nameIdentifiers":[{"nameIdentifier":"763778","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"匠, 伸弥"}],"nameIdentifiers":[{"nameIdentifier":"763779","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"安川, 政宏"}],"nameIdentifiers":[{"nameIdentifier":"763780","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"垣花, 百合子"}],"nameIdentifiers":[{"nameIdentifier":"763781","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"比嘉, 充"}],"nameIdentifiers":[{"nameIdentifier":"763782","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"前川, 康成"}],"nameIdentifiers":[{"nameIdentifier":"763783","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sawada, Shinichi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"763784","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Maekawa, Yasunari","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"763785","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"放射線グラフト陽・陰イオン交換膜を用いた逆電気透析装置の発電性能","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"放射線グラフト陽・陰イオン交換膜を用いた逆電気透析装置の発電性能"}]},"item_type_id":"10004","owner":"1","path":["11"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-06-04"},"publish_date":"2019-06-04","publish_status":"0","recid":"75976","relation_version_is_last":true,"title":["放射線グラフト陽・陰イオン交換膜を用いた逆電気透析装置の発電性能"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:38:52.360415+00:00"}