{"created":"2023-05-15T14:55:42.055481+00:00","id":75632,"links":{},"metadata":{"_buckets":{"deposit":"f4948480-0851-47e8-b83c-bcb348a63c82"},"_deposit":{"created_by":1,"id":"75632","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"75632"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00075632","sets":["10:28"]},"author_link":["799635","799638","799641","799640","799642","799639","799643","799645","799636","799637","799644"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2018-06-25","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"原子力施設で働く作業員が創傷を負い、患部にウランは付着していることが疑われる場合の検査方法として、ろ紙で患部の血液を吸い取り、蛍光X線分析を行う方法を新たに開発したので報告する。ろ紙小片にウラン含有実験用血液を滴下し、マイラとフィルムで密封して、卓上型蛍光X線分析器で分析した。スペクトルにはウランのピークの他に、血液に由来する臭素やルビジウムのピークも観測され、ピークフィッティングによりこれらを分離した。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"European Conference on X-ray Spectrometry(EXRS2018)","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Izumoto, Yukie"}],"nameIdentifiers":[{"nameIdentifier":"799635","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Matsuyama, Tsugufumi"}],"nameIdentifiers":[{"nameIdentifier":"799636","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ishii, Kota"}],"nameIdentifiers":[{"nameIdentifier":"799637","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sakai, Yasuhiro"}],"nameIdentifiers":[{"nameIdentifier":"799638","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Oguri, Yoshiyuki"}],"nameIdentifiers":[{"nameIdentifier":"799639","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yoshii, Hiroshi"}],"nameIdentifiers":[{"nameIdentifier":"799640","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Izumoto, Yukie","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"799641","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Matsuyama, Tsugufumi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"799642","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ishii, Kota","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"799643","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yoshiyuki, Oguri","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"799644","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yoshii, Hiroshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"799645","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Rapid detection of uranium in blood extracted from wounds using X-ray fluorescence analysis","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Rapid detection of uranium in blood extracted from wounds using X-ray fluorescence analysis"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-06-26"},"publish_date":"2018-06-26","publish_status":"0","recid":"75632","relation_version_is_last":true,"title":["Rapid detection of uranium in blood extracted from wounds using X-ray fluorescence analysis"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:49:22.312623+00:00"}