{"created":"2023-05-15T14:55:35.308331+00:00","id":75465,"links":{},"metadata":{"_buckets":{"deposit":"3f7006ab-0281-492f-8274-200b453a1989"},"_deposit":{"created_by":1,"id":"75465","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"75465"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00075465","sets":["7"]},"author_link":["740930","740931","740932","740929"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"69","bibliographicPageStart":"66","bibliographicVolumeNumber":"34","bibliographic_titles":[{"bibliographic_title":"BIO Clinica"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"本稿では,近年需要が高まりつつある次世代重粒子線治療用の,線量分布イメージング検出器開発の取り組みを紹介する。近年,我々は重粒子線のような高LET 放射線でも,ガスの電離,電場によるガス電子増幅,ガスの励起発光をうまく組み合わせることで,高速に線量分布の測定が可能になってきた。本研究では,ガラス製のマイクロ蛍光比例計数管を応用し,LET 依存性もなく,高い空間分解能を有する重粒子線の線量分布イメージング検出器の実用化を目指している。本稿では,本研究開発に至った背景や実証実験におけるこれまでの知見を概説する。","subitem_description_type":"Abstract"}]},"item_10004_relation_10":{"attribute_name":"ISBN","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"17601-04","subitem_relation_type_select":"ISBN"}}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"藤原, 健"}],"nameIdentifiers":[{"nameIdentifier":"740929","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"古場, 裕介"}],"nameIdentifiers":[{"nameIdentifier":"740930","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"三津谷, 有貴"}],"nameIdentifiers":[{"nameIdentifier":"740931","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Koba, Yusuke","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"740932","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"LET 依存性のない重粒子線の線量分布 イメージング検出器の開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"LET 依存性のない重粒子線の線量分布 イメージング検出器の開発"}]},"item_type_id":"10004","owner":"1","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-03-26"},"publish_date":"2019-03-26","publish_status":"0","recid":"75465","relation_version_is_last":true,"title":["LET 依存性のない重粒子線の線量分布 イメージング検出器の開発"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T07:30:10.060686+00:00"}