{"created":"2023-05-15T14:55:32.730959+00:00","id":75408,"links":{},"metadata":{"_buckets":{"deposit":"8fec7f97-5f06-4215-b9b6-4bdd5b2879d8"},"_deposit":{"created_by":1,"id":"75408","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"75408"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00075408","sets":["10:29"]},"author_link":["799629","799634","799628","799623","799627","799633","799631","799632","799625","799630","799626","799624"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2019-03-20","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"東電福島第一原発の廃炉過程ではウランに汚染された可能性のあるがれきが発見される可能性がある。全反射蛍光X線分析法でそのスクリーニングを行うための手法の開発を行った。土壌粉砕物とコンクリート粉砕物を混合した模擬がれきにウラン含有標準液を滴下し、乾燥させて作製した模擬ウラン汚染がれきの酸溶出液を可搬型全反射蛍光X線分析装置で分析した。共存元素の影響を避けるため、U Lβ線での分析を行うこととし、その解析方法を検討した。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"日本原子力学会2019年春の年会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"伊豆本, 幸恵"}],"nameIdentifiers":[{"nameIdentifier":"799623","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松山, 嗣史"}],"nameIdentifiers":[{"nameIdentifier":"799624","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石井, 康太"}],"nameIdentifiers":[{"nameIdentifier":"799625","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高村, 晃大"}],"nameIdentifiers":[{"nameIdentifier":"799626","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"永井, 宏樹"}],"nameIdentifiers":[{"nameIdentifier":"799627","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"酒井, 康弘"}],"nameIdentifiers":[{"nameIdentifier":"799628","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"吉井, 裕"}],"nameIdentifiers":[{"nameIdentifier":"799629","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Izumoto, Yukie","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"799630","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Matsuyama, Tsugufumi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"799631","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ishii, Kota","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"799632","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takamura, Kodai","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"799633","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yoshii, Hiroshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"799634","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"ウラン汚染がれき酸溶出液の全反射蛍光X線分析","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ウラン汚染がれき酸溶出液の全反射蛍光X線分析"},{"subitem_title":"(1)可搬型装置によるスクリーニング","subitem_title_language":"en"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-03-22"},"publish_date":"2019-03-22","publish_status":"0","recid":"75408","relation_version_is_last":true,"title":["ウラン汚染がれき酸溶出液の全反射蛍光X線分析"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:49:22.755835+00:00"}