{"created":"2023-05-15T14:55:03.528418+00:00","id":74831,"links":{},"metadata":{"_buckets":{"deposit":"a599f4c9-a631-4958-98fe-6317ed037995"},"_deposit":{"created_by":1,"id":"74831","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"74831"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00074831","sets":["2"]},"author_link":["739775","739778","739781","739777","739774","739780","739776","739773","739779"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-10","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"1197","bibliographicPageStart":"1195","bibliographic_titles":[{"bibliographic_title":"2018年第15回日本加速器学会年会プロシーディングス"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"At NIRS, re-acceleration of unstable 11C ion beam with the medical synchrotron, HIMAC has been pursuit in order to enable the real-time imaging of carbon ion irradiation into malignant tumor. Up to now 11C6+ ion beam has been tried with very limited intensities of ~10E5 per pulse created with a nuclear reaction of 12C6+ ion beams accelerated by HIMAC (so-called “Projectile Fragment Separation Scheme”) and it was not possible to attain good enough signal to noise ratio to obtain a diagnosable imaging. Recently the usage of 11C ion beam, produced by irradiation of a high intensity proton beam coming from a cyclotron has been investigated. For this purpose, we have studied the separation of the molecular 11CO2+ ion beam from the overwhelming 12CO2+ ion beam with the use of a double focusing magnet. The design of the double focusing magnet as well as the scheme to supply 11C4+ radioactive ions to HIMAC Injector to re-accelerate for cancer therapy is to be presented.","subitem_description_type":"Abstract"}]},"item_10003_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.pasj.jp/web_publish/pasj2018/proceedings/PDF/THP1/THP120.pdf","subitem_relation_type_select":"URI"}}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"野田, 章"}],"nameIdentifiers":[{"nameIdentifier":"739773","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Manfred, Grieser (MPIK)"}],"nameIdentifiers":[{"nameIdentifier":"739774","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮原, 信幸"}],"nameIdentifiers":[{"nameIdentifier":"739775","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"片桐, 健"}],"nameIdentifiers":[{"nameIdentifier":"739776","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北條, 悟"}],"nameIdentifiers":[{"nameIdentifier":"739777","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"涌井, 崇志"}],"nameIdentifiers":[{"nameIdentifier":"739778","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白井, 敏之"}],"nameIdentifiers":[{"nameIdentifier":"739779","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田, 耕司"}],"nameIdentifiers":[{"nameIdentifier":"739780","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Wakui, Takashi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"739781","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"放射性11C+イオンビームの質量分離のための二重集束電磁石の設計","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"放射性11C+イオンビームの質量分離のための二重集束電磁石の設計"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-03-20"},"publish_date":"2019-03-20","publish_status":"0","recid":"74831","relation_version_is_last":true,"title":["放射性11C+イオンビームの質量分離のための二重集束電磁石の設計"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T07:36:14.478706+00:00"}