{"created":"2023-05-15T14:55:03.484280+00:00","id":74830,"links":{},"metadata":{"_buckets":{"deposit":"887a0e1e-90d6-45f2-a73d-2192b8646ffa"},"_deposit":{"created_by":1,"id":"74830","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"74830"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00074830","sets":["2"]},"author_link":["739402","739404","739405","739399","739397","739396","739400","739398","739395","739394","739406","739403","739401"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicVolumeNumber":"68","bibliographic_titles":[{"bibliographic_title":"World Congress on Medical Physics and Biomedical Engineering 2018. IFMBE Proceedings"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Alanine dosimeters are useful tools for measuring both kilo-gray level doses and radiation therapy level doses. The National Metrology Institute of Ja-pan is planning to develop a dose measurement service for carbon-beam therapy. The purpose of this study was to verify that the alanine dosimeter could be used for carbon-beam dosimetry. We irradiated the alanine dosimeter with 60Co-gamma rays and a carbon beam using a range of 10–30 Gy. For the gamma-ray irradiation, the alanine dosimeter was placed in a 5 g cm-2 water phantom. For the carbon-beam irradiation, the spread out Bragg peak of the 290 MeV/u carbon ion was used, and the dosimeter was located at the centre of the peak region. The alanine spectra obtained under the carbon-beam irradiation were almost the same as the spectra under the gamma-ray irradiation. The alanine dosimeter irradiated with the carbon beam show a smaller signal than that obtained under the gamma-ray irradiation for the same dose. The alanine signal increased as the dose in-creased over the entire dosage range for both the gamma-ray and carbon-beam irradiation. This result suggests that the alanine dosimeter has potential for car-bon-beam dosimetry.","subitem_description_type":"Abstract"}]},"item_10003_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1007/978-981-10-9023-3_104","subitem_relation_type_select":"DOI"}}]},"item_10003_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1680-0737","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Yamaguchi, H."}],"nameIdentifiers":[{"nameIdentifier":"739394","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shimizu, M."}],"nameIdentifiers":[{"nameIdentifier":"739395","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Morishita, Y."}],"nameIdentifiers":[{"nameIdentifier":"739396","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hirayama, K."}],"nameIdentifiers":[{"nameIdentifier":"739397","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Satou, Y."}],"nameIdentifiers":[{"nameIdentifier":"739398","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kato, M."}],"nameIdentifiers":[{"nameIdentifier":"739399","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kurosawa, T."}],"nameIdentifiers":[{"nameIdentifier":"739400","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tanaka, T."}],"nameIdentifiers":[{"nameIdentifier":"739401","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Saito, N."}],"nameIdentifiers":[{"nameIdentifier":"739402","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sakama, M."}],"nameIdentifiers":[{"nameIdentifier":"739403","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Fukumura, A."}],"nameIdentifiers":[{"nameIdentifier":"739404","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sakama, Makoto","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"739405","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Fukumura, Akifumi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"739406","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"Feasibility Study of Alanine Dosimeter for Carbon-Beam Dosimetry","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Feasibility Study of Alanine Dosimeter for Carbon-Beam Dosimetry"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-03-19"},"publish_date":"2019-03-19","publish_status":"0","recid":"74830","relation_version_is_last":true,"title":["Feasibility Study of Alanine Dosimeter for Carbon-Beam Dosimetry"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T07:37:35.762595+00:00"}