{"created":"2023-05-15T14:54:56.666317+00:00","id":74665,"links":{},"metadata":{"_buckets":{"deposit":"fabbe497-6926-47b2-9f8f-938d19e1f518"},"_deposit":{"created_by":1,"id":"74665","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"74665"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00074665","sets":["2"]},"author_link":["736651","736646","736650","736644","736645","736642","736647","736643","736649","736648"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-10","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"715","bibliographicPageStart":"711","bibliographic_titles":[{"bibliographic_title":"2018年第15回日本加速器学会年会プロシーディングス"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"An isotope separation on-line (ISOL) system is necessary to provide 11C ions for heavy-ion cancer therapy with simul-taneous verification of the dose distribution using positron emission tomography. To realize the ISOL system, we have developed elementary instruments in the ISOL system, such as a proton-irradiation target, a molecule separation system, and a singly-charged ion source, and performed tests to verify their performances. As a next step of the development, we are planning to start an experiment of on-line production of singly-charged 11C ions at the proton irradiation port of the NIRS-cyclotron facility. In this paper, we present those elementary instruments, their performance and the on-line production experiment.","subitem_description_type":"Abstract"}]},"item_10003_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.pasj.jp/web_publish/pasj2018/proceedings/index.html","subitem_relation_type_select":"URI"}}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"片桐, 健"}],"nameIdentifiers":[{"nameIdentifier":"736642","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"涌井, 崇志"}],"nameIdentifiers":[{"nameIdentifier":"736643","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"永津, 弘太郎"}],"nameIdentifiers":[{"nameIdentifier":"736644","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北條, 悟"}],"nameIdentifiers":[{"nameIdentifier":"736645","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田, 章"}],"nameIdentifiers":[{"nameIdentifier":"736646","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Katagiri, Ken","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"736647","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Wakui, Takashi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"736648","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nagatsu, Kotaro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"736649","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hojo, Satoru","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"736650","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Noda, Akira","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"736651","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"RI ビームがん治療用ISOL システムの開発: 1 価C-11 イオン生成実験","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"RI ビームがん治療用ISOL システムの開発: 1 価C-11 イオン生成実験"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-03-13"},"publish_date":"2019-03-13","publish_status":"0","recid":"74665","relation_version_is_last":true,"title":["RI ビームがん治療用ISOL システムの開発: 1 価C-11 イオン生成実験"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T07:49:05.712539+00:00"}