@article{oai:repo.qst.go.jp:00074657, author = {Glynnis Mae Quinones, SAQUILAYAN and 柏木, 美恵子 and 戸張, 博之 and 平塚, 淳一 and 市川, 雅浩 and 梅田, 尚孝 and 渡邊, 和弘 and 和田, 元 and 笹尾, 真美子 and mae quinones Saquilayan, Glynnis and Kashiwagi, Mieko and Tobari, Hiroyuki and Hiratsuka, Junichi and Ichikawa, Masahiro and Umeda, Naotaka and Watanabe, Kazuhiro}, journal = {AIP Conference Proceedings}, month = {Dec}, note = {A thermal beam emittance measurement method is developed specifically to measure high power density beams for the ITER neutral beam injection system (NBI)’s. A one-dimensional carbon-fiber composite (CFC) target is utilized to withstand the high current densities of the negative hydrogen beam making the beam emittance measurement possible. Schemes for the emittance measurement were discussed since beam instabilities are present in various stages of the beam phase. The allowable time for the measurement will be less than 2 seconds and it’s necessary to monitor the CFC temperature to not exceed 2000°C. The proposed measurement scheme to minimize beam instabilities is through the constant operation of the arc discharge and pulsed beam extraction. Mechanical structures are also being designed for rapid measurements to select different phases of the beam and for implementing the measurement system to long pulse beam operation.}, pages = {040014-1--040014-7}, title = {Methods of Beam Emittance Measurements of High Power Negative Ion Beams for NBIs}, volume = {2052}, year = {2018} }