{"created":"2023-05-15T14:53:54.335750+00:00","id":73400,"links":{},"metadata":{"_buckets":{"deposit":"23eb913e-58a2-41f8-ab01-079673474d40"},"_deposit":{"created_by":1,"id":"73400","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"73400"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00073400","sets":["1"]},"author_link":["722903","722902","722901","722900"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-05","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"359","bibliographicPageStart":"356","bibliographicVolumeNumber":"18","bibliographic_titles":[{"bibliographic_title":"Nuclear Materials and Energy"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"JT-60Uのネオンを入射した高加熱パワーのHモード放電において,ダイバータにおける高電離ネオンイオン(Ne7+)のスペクトル線を見出し,その空間分布を高電離炭素イオン(C3+)の空間分布とともにコンピュータトモグラフィーによって可視化した. Ne7+ はX点の強磁場側に分布していたことを明らかにした.ただし,この状態は数秒間しか維持できず,Ne7+ の発光強度は低下するとともにストライク点付近に移動した.代わってC3+がX点の強磁場側で強い放射を放つ状態に変化した.NeあるいはCが強い放射を放つためにはそれぞれに適切な電子温度に制御する必要があると考えられる.","subitem_description_type":"Abstract"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1016/j.nme.2019.01.020","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://doi.org/10.1016/j.nme.2019.01.020"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1016/j.nme.2019.01.020","subitem_relation_type_select":"DOI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2352-1791 ","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"仲野, 友英"}],"nameIdentifiers":[{"nameIdentifier":"722900","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"朝倉, 伸幸"}],"nameIdentifiers":[{"nameIdentifier":"722901","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"仲野 友英","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"722902","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"朝倉 伸幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"722903","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Spatial distribution of Ne ions in detached divertor plasmas of JT-60U","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Spatial distribution of Ne ions in detached divertor plasmas of JT-60U"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-02-18"},"publish_date":"2019-02-18","publish_status":"0","recid":"73400","relation_version_is_last":true,"title":["Spatial distribution of Ne ions in detached divertor plasmas of JT-60U"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:29:43.568586+00:00"}