{"created":"2023-05-15T14:53:47.951715+00:00","id":73260,"links":{},"metadata":{"_buckets":{"deposit":"1a911d74-5296-43b6-a11e-c0655d984217"},"_deposit":{"created_by":1,"id":"73260","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"73260"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00073260","sets":["10:27"]},"author_link":["721817","721818"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2016-09-14","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Superheated bubble detector (SBD) detects radiation via phase transition of superheated droplets in polymer gel to visible bubbles triggered by the energy deposition by radiation. Because the unit size concerning the phase transition is considered to be sub μm, we expect the response of SBD reflects microdosimetric information of incident radiation and an index of biological effectiveness. The current status of the R&D of SBD and its response to therapeutic carbon beam is introduced.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第77回応用物理学会秋季学術講演会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"松藤, 成弘"}],"nameIdentifiers":[{"nameIdentifier":"721817","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松藤 成弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"721818","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"バブル検出器による重粒子線の線質評価の可能性","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"バブル検出器による重粒子線の線質評価の可能性"}]},"item_type_id":"10005","owner":"1","path":["27"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-09-21"},"publish_date":"2016-09-21","publish_status":"0","recid":"73260","relation_version_is_last":true,"title":["バブル検出器による重粒子線の線質評価の可能性"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:31:16.221626+00:00"}