{"created":"2023-05-15T14:53:38.378894+00:00","id":73047,"links":{},"metadata":{"_buckets":{"deposit":"f07b4d12-7fdd-447f-bc06-39b3f67006f3"},"_deposit":{"created_by":1,"id":"73047","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"73047"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00073047","sets":["10:28"]},"author_link":["719882","719887","719888","719884","719886","719880","719885","719883","719879","719881"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2018-11-15","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"[18F]FDG注射液には、合成過程においてメタノール、エタノール、アセトニトリルの混入が考えられ、残留溶媒濃度の測定が求められている。放医研では日本の多くのPET施設から残留有機溶媒の分析を受託しており、これまでに蓄積したデーターから、合成装置機種間における残留有機溶媒濃度の差異を中心に考察した。[18F]FDG注射液中の残留有機溶媒濃度は合成装置間で明らかな違いが見られた。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第58回日本核医学会学術総会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"橋本, 裕輝"}],"nameIdentifiers":[{"nameIdentifier":"719879","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"狩谷, 香"}],"nameIdentifiers":[{"nameIdentifier":"719880","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"河村, 和紀"}],"nameIdentifiers":[{"nameIdentifier":"719881","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"脇, 厚生"}],"nameIdentifiers":[{"nameIdentifier":"719882","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"張, 明栄"}],"nameIdentifiers":[{"nameIdentifier":"719883","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"橋本 裕輝","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"719884","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"狩谷 香","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"719885","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"河村 和紀","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"719886","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"脇 厚生","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"719887","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"張 明栄","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"719888","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"[18F]FDG注射液中の残留有機溶媒濃度の合成装置間による差異","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"[18F]FDG注射液中の残留有機溶媒濃度の合成装置間による差異"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-11-21"},"publish_date":"2018-11-21","publish_status":"0","recid":"73047","relation_version_is_last":true,"title":["[18F]FDG注射液中の残留有機溶媒濃度の合成装置間による差異"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:33:25.351171+00:00"}