{"created":"2023-05-15T14:53:33.502929+00:00","id":72935,"links":{},"metadata":{"_buckets":{"deposit":"ffec2342-1e25-473c-9638-3f0620f49e29"},"_deposit":{"created_by":1,"id":"72935","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"72935"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00072935","sets":["10:28"]},"author_link":["718695","718689","718688","718687","718690","718692","718691","718693","718694"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2018-09-13","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"分子整列制御およびイオン化異方性を用いたレーザー同位体分離の重元素に対する有用性を評価するため、IBrの臭素同位体選択イオン化実験を行った。ナノ秒パルスの後半部分をレーザープラズマで打ち消して作った波形整形ナノ秒パルスを用いて分子整列を行い、fsパルスでイオン化した。fsパルスによる分子整列の場合と、結果を比較した。波形整形ナノ秒パルスでは、集光強度が7×10^10 W/cm2と低いにもかかわらず、同位体選択イオン化が実現した。その選択性はI81Br/I79Br=0.93~1.06であった。一方、fsパルスでは集光強度が2桁以上高く(1.0×1013 W/cm2)出来たため、波形整形パルスの場合よりも高い選択性が得られた(I81Br/I79Br=0.80~1.25)。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第12回分子科学討論会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"赤木, 浩"}],"nameIdentifiers":[{"nameIdentifier":"718687","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"熊田, 高之"}],"nameIdentifiers":[{"nameIdentifier":"718688","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"乙部, 智仁"}],"nameIdentifiers":[{"nameIdentifier":"718689","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"板倉, 隆二"}],"nameIdentifiers":[{"nameIdentifier":"718690","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"長谷川, 宗良"}],"nameIdentifiers":[{"nameIdentifier":"718691","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大島, 康裕"}],"nameIdentifiers":[{"nameIdentifier":"718692","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"赤木 浩","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"718693","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"乙部 智仁","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"718694","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"板倉 隆二","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"718695","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"波形整形ナノ秒パルスによる分子整列制御を用いたIBr同位体選択的イオン化","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"波形整形ナノ秒パルスによる分子整列制御を用いたIBr同位体選択的イオン化"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-09-14"},"publish_date":"2018-09-14","publish_status":"0","recid":"72935","relation_version_is_last":true,"title":["波形整形ナノ秒パルスによる分子整列制御を用いたIBr同位体選択的イオン化"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:34:29.731631+00:00"}