{"created":"2023-05-15T14:53:32.094863+00:00","id":72903,"links":{},"metadata":{"_buckets":{"deposit":"174fe07c-99fa-4ad1-aaf1-a1f4a2bd4c60"},"_deposit":{"created_by":1,"id":"72903","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"72903"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00072903","sets":["10:28"]},"author_link":["718356","718353","718360","718362","718358","718355","718364","718354","718366","718365","718363","718359","718361","718357","718352"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2018-08-09","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"At NIRS, re-acceleration of unstable 11C ion beam with the medical synchrotron, HIMAC has been pursuit in order to enable the real-time imaging of carbon ion irradiation into malignant tumor. Up to now 11C6+ ion beam has been tried with very limited intensities of ~10E5 per pulse created with a nuclear reaction of 12C6+ ion beams accelerated by HIMAC (so-called “Projectile Fragment Separation Scheme”) and it was not possible to attain good enough signal to noise ratio to obtain a diagnosable imaging. Recently the usage of 11C ion beam, produced by irradiation of a high intensity proton beam coming from a cyclotron has been investigated. For this purpose, we have studied the separation of the molecular 11CO2+ ion beam from the overwhelming 12CO2+ ion beam with the use of a double focusing magnet. The design of the double focusing magnet as well as the scheme to supply 11C4+ radioactive ions to HIMAC Injector to re-accelerate for cancer therapy is to be presented. ","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第15回日本加速器学会年会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"野田, 章"}],"nameIdentifiers":[{"nameIdentifier":"718352","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Grieser, (MPIK) Manfred"}],"nameIdentifiers":[{"nameIdentifier":"718353","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮原, 信幸"}],"nameIdentifiers":[{"nameIdentifier":"718354","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"片桐, 健"}],"nameIdentifiers":[{"nameIdentifier":"718355","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北條, 悟"}],"nameIdentifiers":[{"nameIdentifier":"718356","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"涌井, 崇志"}],"nameIdentifiers":[{"nameIdentifier":"718357","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白井, 敏之"}],"nameIdentifiers":[{"nameIdentifier":"718358","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田, 耕司"}],"nameIdentifiers":[{"nameIdentifier":"718359","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田 章","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"718360","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮原 信幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"718361","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"片桐 健","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"718362","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北條 悟","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"718363","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"涌井 崇志","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"718364","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白井 敏之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"718365","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田 耕司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"718366","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"放射性11C+ イオンビームの質量分離のための二重収束電磁石の設計","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"放射性11C+ イオンビームの質量分離のための二重収束電磁石の設計"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-08-23"},"publish_date":"2018-08-23","publish_status":"0","recid":"72903","relation_version_is_last":true,"title":["放射性11C+ イオンビームの質量分離のための二重収束電磁石の設計"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:34:50.259797+00:00"}