{"created":"2023-05-15T14:53:28.582196+00:00","id":72823,"links":{},"metadata":{"_buckets":{"deposit":"ce3267de-b4a3-4909-8794-4bb677cb41ac"},"_deposit":{"created_by":1,"id":"72823","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"72823"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00072823","sets":["10:28"]},"author_link":["717425","717424"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2018-06-04","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In carbon-ion radiotherapy, therapeutic carbon-ion beams occasionally penetrate an immobilization device of patients. The microscopic fine structures of the device may enlarge the Bragg-peak width of the beam as compared to the non-porous solid materials with the same water-equivalent thickness. In this study, we investigate this Bragg-peak degradation effect on patient dose distributions in scanned carbon-ion","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"World Congress on Medical Physics and Biomedical Engineering 2018 (IUPESM2018)","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Inaniwa, Taku"}],"nameIdentifiers":[{"nameIdentifier":"717424","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"稲庭 拓","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"717425","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Bragg-peak degradation of a carbon-ion beam penetrating a patient immobilization device with microscopic fine structures","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Bragg-peak degradation of a carbon-ion beam penetrating a patient immobilization device with microscopic fine structures"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-06-14"},"publish_date":"2018-06-14","publish_status":"0","recid":"72823","relation_version_is_last":true,"title":["Bragg-peak degradation of a carbon-ion beam penetrating a patient immobilization device with microscopic fine structures"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:35:40.538283+00:00"}