{"created":"2023-05-15T14:53:22.242967+00:00","id":72679,"links":{},"metadata":{"_buckets":{"deposit":"2a3714c9-f6d3-4513-9d50-3ad0c02856ec"},"_deposit":{"created_by":1,"id":"72679","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"72679"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00072679","sets":["10:28"]},"author_link":["715819","715823","715820","715822","715818","715821"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2017-10-17","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"逆電気透析(RED)発電は、陽イオン交換膜(CEM)と陰イオン交換膜(AEM)を用いて海水と淡水から電気を産生する極めてクリーンな発電技術である。本研究では、放射線グラフト重合法により作製できるCEMとAEMのRED発電への応用可能性を検討するため、これらの輸送特性として食塩水中における膜抵抗を測定した。CEM、AEM共に、イオン交換容量(IEC)が上がると膜抵抗は急激に減少した。IEC=2.4 mmol/gのCEMと1.6 mmol/gのAEMは、それぞれ0.28(市販膜の10%)、0.39 Ω cm2(市販膜の17%)という非常に低い膜抵抗を示した。これらのグラフト型CEMとAEMのペアを用いることで、市販膜の場合よりも発電出力を38%向上できることが推算された。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"5th International Conference on Nanotechnology and Materials Science","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"澤田, 真一"}],"nameIdentifiers":[{"nameIdentifier":"715818","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"安川, 政宏"}],"nameIdentifiers":[{"nameIdentifier":"715819","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"比嘉, 充"}],"nameIdentifiers":[{"nameIdentifier":"715820","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Maekawa, Yasunari"}],"nameIdentifiers":[{"nameIdentifier":"715821","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"澤田 真一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"715822","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"前川 康成","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"715823","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Preparation of cation and anion exchange membranes for reverse electrodialysis by radiation-induced grafting method","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Preparation of cation and anion exchange membranes for reverse electrodialysis by radiation-induced grafting method"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-03-07"},"publish_date":"2018-03-07","publish_status":"0","recid":"72679","relation_version_is_last":true,"title":["Preparation of cation and anion exchange membranes for reverse electrodialysis by radiation-induced grafting method"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:37:14.809438+00:00"}