{"created":"2023-05-15T14:53:14.715782+00:00","id":72538,"links":{},"metadata":{"_buckets":{"deposit":"a9d2c419-d2cb-481e-b268-82b099972cb2"},"_deposit":{"created_by":1,"id":"72538","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"72538"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00072538","sets":["10:28"]},"author_link":["714397","714399","714398"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2017-11-24","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"By applying Direct 1 Step (D1S) MCNP with the modified nuclear data library (ACE file), it is possible to calculate the shutdown dose rate in A-FNS facility with high accuracy. In order to create the ACE files for D1S MCNP, we develop the creation code. Using this code and Fusion Evaluated Nuclear Data Libraries FENDL-3.1, we newly create the ACE files for D1S MCNP for the evaluation of the shutdown dose rate in A-FNS. We conduct the benchmark calculation by using the D1S MCNP and the newly created ACE files. From the benchmark calculation results, it is confirmed that the ACE files are successfully created.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"Plasma Conference 2017 ","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"佐藤, 聡"}],"nameIdentifiers":[{"nameIdentifier":"714397","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小迫, 和明"}],"nameIdentifiers":[{"nameIdentifier":"714398","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐藤 聡","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"714399","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Nuclear Data Library for Shutdown Dose Rate Calculation on Advanced Fusion Neutron Source Facility","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Nuclear Data Library for Shutdown Dose Rate Calculation on Advanced Fusion Neutron Source Facility"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-11-21"},"publish_date":"2017-11-21","publish_status":"0","recid":"72538","relation_version_is_last":true,"title":["Nuclear Data Library for Shutdown Dose Rate Calculation on Advanced Fusion Neutron Source Facility"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:38:42.401418+00:00"}