{"created":"2023-05-15T14:53:11.296706+00:00","id":72486,"links":{},"metadata":{"_buckets":{"deposit":"4e059c78-7eae-4b74-92a8-80c78a62556d"},"_deposit":{"created_by":1,"id":"72486","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"72486"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00072486","sets":["10:28"]},"author_link":["713879","713873","713878","713876","713870","713872","713869","713875","713877","713868","713874","713871"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2017-10-06","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"放医研分イメ診断・治療用として利用されている64Cu(T1/2 12.7h, β±)は、主に64Ni(p,n)64Cu反応を利用し、院内製造が可能なことから、今後、より需要の見込まれる核種のひとつである。ところで、高品質な64Cuを製造するためには、高品質な64Niターゲットの製造は不可欠だが、それとともに、ターゲットの品質を保持したまま製品として出力する化学分離過程もまた重要になってくる。その中で、特に個人の経験・技量が大きく作用する装置の洗浄・組み立て等の前準備は、不純物金属元素の製品混入の主要因でもあることから、製品品質へのインパクトが大きい。我々は個人技量による品質のばらつきを解消するため、ディスポーザブル部品で構成されている分離精製装置を試作した。学会では、それを用いた試験製造・評価について報告する。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第57回日本核医学会学術総会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"大矢, 智幸"}],"nameIdentifiers":[{"nameIdentifier":"713868","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木, 寿"}],"nameIdentifiers":[{"nameIdentifier":"713869","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"峯岸, 克行"}],"nameIdentifiers":[{"nameIdentifier":"713870","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"深田, 正美"}],"nameIdentifiers":[{"nameIdentifier":"713871","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"永津, 弘太郎"}],"nameIdentifiers":[{"nameIdentifier":"713872","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"張, 明栄"}],"nameIdentifiers":[{"nameIdentifier":"713873","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大矢 智幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713874","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木 寿","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713875","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"峯岸 克行","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713876","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"深田 正美","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713877","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"永津 弘太郎","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713878","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"張 明栄","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713879","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"ディスポーザブル型64Cu製造装置の開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ディスポーザブル型64Cu製造装置の開発"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-10"},"publish_date":"2017-10-10","publish_status":"0","recid":"72486","relation_version_is_last":true,"title":["ディスポーザブル型64Cu製造装置の開発"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:39:18.608914+00:00"}