{"created":"2023-05-15T14:53:07.569567+00:00","id":72433,"links":{},"metadata":{"_buckets":{"deposit":"9a8c98b7-c8cd-40b4-a2da-8740d1d1eeca"},"_deposit":{"created_by":1,"id":"72433","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"72433"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00072433","sets":["10:28"]},"author_link":["713429","713430","713434","713432","713443","713441","713428","713427","713442","713436","713431","713437","713440","713435","713439","713433","713438"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2017-09-06","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"67Cu(半減期62時間)は、がん治療に適したベータ線(平均エネルギー141 keV)と画像化に適したガンマ線(185 keV)を同時に放出するため、がん治療用核種として有望視されているが、大量に高品質の67Cuを製造する方法が限られているため、研究開発が限定的である。そこで我々は、高崎量子応用研究所AVFサイクロトロンにて重陽子ビームをベリリウム標的に照射する事で発生する高速中性子を68ZnOに照射することにより67Cuを製造する手法の開発を行っており、これまでに、動物実験が可能な高品質 67Cuの分離精製法を確立した。今回は、製造した67Cuの比放射能を、DOTA標識法により評価したので報告する。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"2017日本放射化学会年会・第61回放射化学討論会 ","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"橋本, 和幸"}],"nameIdentifiers":[{"nameIdentifier":"713427","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"川端, 方子"}],"nameIdentifiers":[{"nameIdentifier":"713428","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐伯, 秀也"}],"nameIdentifiers":[{"nameIdentifier":"713429","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐藤, 俊一"}],"nameIdentifiers":[{"nameIdentifier":"713430","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"塚田, 和明"}],"nameIdentifiers":[{"nameIdentifier":"713431","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"須郷, 由美"}],"nameIdentifiers":[{"nameIdentifier":"713432","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"永井, 泰樹"}],"nameIdentifiers":[{"nameIdentifier":"713433","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"初川, 雄一"}],"nameIdentifiers":[{"nameIdentifier":"713434","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石岡, 典子"}],"nameIdentifiers":[{"nameIdentifier":"713435","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"橋本 和幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713436","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"川端 方子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713437","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐伯 秀也","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713438","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"塚田 和明","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713439","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"須郷 由美","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713440","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"永井 泰樹","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713441","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"初川 雄一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713442","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石岡 典子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713443","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"重陽子照射で発生する加速器中性子によって製造するがん治療用67Cuの比放射能評価","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"重陽子照射で発生する加速器中性子によって製造するがん治療用67Cuの比放射能評価"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-09-08"},"publish_date":"2017-09-08","publish_status":"0","recid":"72433","relation_version_is_last":true,"title":["重陽子照射で発生する加速器中性子によって製造するがん治療用67Cuの比放射能評価"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:39:53.968453+00:00"}