{"created":"2023-05-15T14:53:05.776673+00:00","id":72406,"links":{},"metadata":{"_buckets":{"deposit":"1e275b44-868b-479b-bf67-37b1cdf1ce53"},"_deposit":{"created_by":1,"id":"72406","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"72406"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00072406","sets":["10:28"]},"author_link":["713215","713212","713216","713218","713206","713210","713211","713214","713207","713209","713213","713208","713217"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2017-08-02","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"重粒子線によるがん治療はその線量集中性と大きなRBEによる高い治療効果を実現し、装置の小型化とも相俟って広範な普及に向けての取り組みが世界各地で進行している。この治療を重要臓器に隣接した腫瘍を患っている患者さんへの適用をも可能とするため、positron emitterの不安定核11Cイオンビームを充分な強度で治療に供給することを目指して、 サイクロトロンからの高強度ビームで生成したビームをHIMACシンクロトロンで再加速する(Target Fragment Scheme)ための核種分離システムと多価チャージ実現のためのチャージブリーダーの設計・検討の結果を紹 介したい。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"日本加速器学会 第14回年会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"野田, 章"}],"nameIdentifiers":[{"nameIdentifier":"713206","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"片桐, 健"}],"nameIdentifiers":[{"nameIdentifier":"713207","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北條, 悟"}],"nameIdentifiers":[{"nameIdentifier":"713208","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"涌井, 崇志"}],"nameIdentifiers":[{"nameIdentifier":"713209","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白井, 敏之"}],"nameIdentifiers":[{"nameIdentifier":"713210","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田, 耕司"}],"nameIdentifiers":[{"nameIdentifier":"713211","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Grieser, (MPI-K) Manfred"}],"nameIdentifiers":[{"nameIdentifier":"713212","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田 章","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713213","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"片桐 健","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713214","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北條 悟","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713215","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"涌井 崇志","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713216","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白井 敏之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713217","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田 耕司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713218","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"11C不安定核イオンビームの分離及び多価イオンへの転換システム","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"11C不安定核イオンビームの分離及び多価イオンへの転換システム"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-08-09"},"publish_date":"2017-08-09","publish_status":"0","recid":"72406","relation_version_is_last":true,"title":["11C不安定核イオンビームの分離及び多価イオンへの転換システム"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:40:11.385680+00:00"}