{"created":"2023-05-15T14:52:52.172244+00:00","id":72184,"links":{},"metadata":{"_buckets":{"deposit":"fe0e0fa6-7585-4114-9ab8-347138925650"},"_deposit":{"created_by":1,"id":"72184","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"72184"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00072184","sets":["10:28"]},"author_link":["710806","710807","710794","710795","710805","710803","710798","710799","710797","710802","710804","710800","710796","710801"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2016-09-05","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"核融合原型炉における重要課題であるダイバータ熱制御について、大半径8m級の原型炉を対象として、SONICコードを用いた解析を行った。熱負荷低減のための非接触ダイバータ形成に不利である低SOL密度においても、主プラズマから流出する熱の80%を不純物放射させることができれば、部分非接触ダイバータが形成され、熱負荷を8MW/m2程度に低減できることがわかった。しかし、ピークイオン温度は300eVと非常に高く、損耗が問題となる。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"29th edition of the Symposium on Fusion Technology","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"星野, 一生"}],"nameIdentifiers":[{"nameIdentifier":"710794","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"朝倉, 伸幸"}],"nameIdentifiers":[{"nameIdentifier":"710795","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"徳永, 晋介"}],"nameIdentifiers":[{"nameIdentifier":"710796","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"本間, 裕貴"}],"nameIdentifiers":[{"nameIdentifier":"710797","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"清水, 勝宏"}],"nameIdentifiers":[{"nameIdentifier":"710798","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"坂本, 宜照"}],"nameIdentifiers":[{"nameIdentifier":"710799","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"飛田, 健次"}],"nameIdentifiers":[{"nameIdentifier":"710800","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"星野 一生","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"710801","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"朝倉 伸幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"710802","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"徳永 晋介","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"710803","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"本間 裕貴","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"710804","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"清水 勝宏","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"710805","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"坂本 宜照","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"710806","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"飛田 健次","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"710807","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Physics design study of the divertor power handling in 8m-sized DEMO reactor","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Physics design study of the divertor power handling in 8m-sized DEMO reactor"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-03-13"},"publish_date":"2017-03-13","publish_status":"0","recid":"72184","relation_version_is_last":true,"title":["Physics design study of the divertor power handling in 8m-sized DEMO reactor"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:42:47.927379+00:00"}