{"created":"2023-05-15T14:52:45.084060+00:00","id":72022,"links":{},"metadata":{"_buckets":{"deposit":"e49d54f7-910f-418e-adc4-17e2d953b333"},"_deposit":{"created_by":1,"id":"72022","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"72022"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00072022","sets":["10:28"]},"author_link":["709379","709373","709377","709376","709371","709378","709368","709370","709369","709367","709372","709374","709375"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2016-09-15","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In recent years, the production of radionuclides for Targeted Radionuclide Therapy (TRT) with the NIRS-930 cyclotron has been one of the most important activities in National Institutes for Quantum and Radiological Science and Technology (QST). In the production of 211At, for example, a target material with low melting point is irradiated with a high intensity beam. A vertical beam line have the advantage in irradiation with low-melting-point target. Therefore a vertical beam line has been modified for the production of radionuclides. This line was used for neutron source with beryllium target. The beam intensity and beam energy are important parameters for the effective production of radionuclide for TRT. In order to increase beam intensity, the acceleration phase and injection energy have been optimized by measuring beam phase. The beam energy has been measured by TOF and adjusted by tuning the acceleration frequency.\nThose studies and improvement are reported.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"21st International Conference on Cyclotrons and their Applications","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Satoru, Hojo"}],"nameIdentifiers":[{"nameIdentifier":"709367","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ken, Katagiri"}],"nameIdentifiers":[{"nameIdentifier":"709368","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Masao, Nakao"}],"nameIdentifiers":[{"nameIdentifier":"709369","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Akira, Noda"}],"nameIdentifiers":[{"nameIdentifier":"709370","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Koji, Noda"}],"nameIdentifiers":[{"nameIdentifier":"709371","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Akinori, Sugiura"}],"nameIdentifiers":[{"nameIdentifier":"709372","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takashi, Wakui"}],"nameIdentifiers":[{"nameIdentifier":"709373","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北條 悟","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"709374","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"片桐 健","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"709375","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田 章","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"709376","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田 耕司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"709377","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"杉浦 彰則","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"709378","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"涌井 崇志","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"709379","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"IMPROVEMENT OF THE NIRS-930 CYCLOTRON FOR TARGETED RADIONUCLIDE THERAPY","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"IMPROVEMENT OF THE NIRS-930 CYCLOTRON FOR TARGETED RADIONUCLIDE THERAPY"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-09-20"},"publish_date":"2016-09-20","publish_status":"0","recid":"72022","relation_version_is_last":true,"title":["IMPROVEMENT OF THE NIRS-930 CYCLOTRON FOR TARGETED RADIONUCLIDE THERAPY"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:44:42.280699+00:00"}