@misc{oai:repo.qst.go.jp:00072022, author = {Satoru, Hojo and Ken, Katagiri and Masao, Nakao and Akira, Noda and Koji, Noda and Akinori, Sugiura and Takashi, Wakui and 北條 悟 and 片桐 健 and 野田 章 and 野田 耕司 and 杉浦 彰則 and 涌井 崇志}, month = {Sep}, note = {In recent years, the production of radionuclides for Targeted Radionuclide Therapy (TRT) with the NIRS-930 cyclotron has been one of the most important activities in National Institutes for Quantum and Radiological Science and Technology (QST). In the production of 211At, for example, a target material with low melting point is irradiated with a high intensity beam. A vertical beam line have the advantage in irradiation with low-melting-point target. Therefore a vertical beam line has been modified for the production of radionuclides. This line was used for neutron source with beryllium target. The beam intensity and beam energy are important parameters for the effective production of radionuclide for TRT. In order to increase beam intensity, the acceleration phase and injection energy have been optimized by measuring beam phase. The beam energy has been measured by TOF and adjusted by tuning the acceleration frequency. Those studies and improvement are reported., 21st International Conference on Cyclotrons and their Applications}, title = {IMPROVEMENT OF THE NIRS-930 CYCLOTRON FOR TARGETED RADIONUCLIDE THERAPY}, year = {2016} }