{"created":"2023-05-15T14:52:37.509319+00:00","id":71849,"links":{},"metadata":{"_buckets":{"deposit":"e14c1271-ca02-40f2-abce-b6d061b282e8"},"_deposit":{"created_by":1,"id":"71849","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"71849"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00071849","sets":["10:28"]},"author_link":["707444","707448","707451","707452","707447","707446","707445","707450","707449","707443"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2015-11-06","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"【目的】虚血診断目的で位相解析ソフトウエアを使用する際のQGS、ETB、HFV間での互換性について検討した。【方法】虚血診断目的で201Tl SPECTが施行された97例のデータを3つのソフトウエアを用い位相解析指標のBand Width(BW)及びPhase Standard Deviation(SD)の相関を後顧的に検討するとともにBland-Altman plotによる解析を行った。また対象を虚血スコアに基づき正常、虚血、梗塞、梗塞+虚血群の4群に分け負荷、安静時の位相解析指標を比較した。【結果】相関係数は両指標とも負荷時に0.47から0.64、安静時は0.26~0.49であり安静時で劣化した。Bland-Altman plot解析ではBiasはSDで6.0以内、BWで11.0以内であったが95%CIがSDでBiasの5倍、BWで15倍であり安静時検査で劣化した。また4群間の比較では両指標とも梗塞+虚血群が梗塞群と比べ高い傾向があったが有意差は無かった。また正常群と虚血群間にも有意な差は無かった。【結論】虚血診断目的で位相解析指標を求める際にQGS、ETB、HFV間の互換性は良好では無いが、虚血診断能にも大きな差は無いと思われた。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第55回日本核医学会学術総会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"長町, 茂樹"}],"nameIdentifiers":[{"nameIdentifier":"707443","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"西井, 龍一"}],"nameIdentifiers":[{"nameIdentifier":"707444","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"水谷, 陽一"}],"nameIdentifiers":[{"nameIdentifier":"707445","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"藤田, 晴吾"}],"nameIdentifiers":[{"nameIdentifier":"707446","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"平井, 俊範"}],"nameIdentifiers":[{"nameIdentifier":"707447","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"二見, 繁美"}],"nameIdentifiers":[{"nameIdentifier":"707448","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"清原, 省吾"}],"nameIdentifiers":[{"nameIdentifier":"707449","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"若松, 秀行"}],"nameIdentifiers":[{"nameIdentifier":"707450","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鬼塚, 久充"}],"nameIdentifiers":[{"nameIdentifier":"707451","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"西井 龍一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"707452","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"心筋虚血診断における位相解析ソフトウエアの互換性比較 ","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"心筋虚血診断における位相解析ソフトウエアの互換性比較 "}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-11-11"},"publish_date":"2015-11-11","publish_status":"0","recid":"71849","relation_version_is_last":true,"title":["心筋虚血診断における位相解析ソフトウエアの互換性比較 "],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:46:40.722387+00:00"}