{"created":"2023-05-15T14:52:37.422283+00:00","id":71847,"links":{},"metadata":{"_buckets":{"deposit":"855e497c-147f-4979-a5f3-aad6af13c7d1"},"_deposit":{"created_by":1,"id":"71847","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"71847"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00071847","sets":["10:28"]},"author_link":["707432","707426","707429","707430","707415","707427","707431","707421","707422","707424","707425","707419","707416","707417","707420","707423","707418","707428"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2015-11-06","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"For quality assurance (QA) of therapeutic ion beams, QA tool having high spatial resolution and quick verification is required. The imaging system with a fluorescent screen is suitable for QA procedure. We developed a quick verification system (NQA-SCN) using a fluorescent screen with a charge-coupled device (CCD) camera for the sake of two dimensional dosimetry. The NQA-SCN is compact size to attach to irradiation port and water column. Several types of corrections were applied to the raw image obtained by the NQA-SCN. Our goal is to use the NQA-SCN for three-dimensional dose verification. In carbon-ion therapy, the fluorescent light is decreased by suffering from quenching effect due to the increased linear energy transfer (LET) in the Bragg peak. For the use of three-dimensional dose verification, as a first approach, we investigated the quenching effect of carbon-ion beam in water. Also, to evaluate the performance of NQA-SCN, we carried out experiments concerning QA procedures.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"19th International conference on accelerators and beam utilizations (ICABU2015)","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hara, Yousuke"}],"nameIdentifiers":[{"nameIdentifier":"707415","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Furukawa, Takuji"}],"nameIdentifiers":[{"nameIdentifier":"707416","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mizushima, Kota"}],"nameIdentifiers":[{"nameIdentifier":"707417","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Saotome, Naoya"}],"nameIdentifiers":[{"nameIdentifier":"707418","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Saraya, Yuichi"}],"nameIdentifiers":[{"nameIdentifier":"707419","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tansho, Ryohei"}],"nameIdentifiers":[{"nameIdentifier":"707420","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takeshita, Eri"}],"nameIdentifiers":[{"nameIdentifier":"707421","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shirai, Toshiyuki"}],"nameIdentifiers":[{"nameIdentifier":"707422","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Noda, Koji"}],"nameIdentifiers":[{"nameIdentifier":"707423","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"原 洋介","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"707424","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"古川 卓司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"707425","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"水島 康太","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"707426","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"早乙女 直也","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"707427","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"皿谷 有一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"707428","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"丹正 亮平","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"707429","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"竹下 英里","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"707430","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白井 敏之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"707431","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田 耕司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"707432","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Development of Compact Dose Verification System Using a Fluorescent Screen for Carbon-ion Therapy","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development of Compact Dose Verification System Using a Fluorescent Screen for Carbon-ion Therapy"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-11-11"},"publish_date":"2015-11-11","publish_status":"0","recid":"71847","relation_version_is_last":true,"title":["Development of Compact Dose Verification System Using a Fluorescent Screen for Carbon-ion Therapy"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:46:42.067487+00:00"}