{"created":"2023-05-15T14:52:33.178671+00:00","id":71750,"links":{},"metadata":{"_buckets":{"deposit":"57211f67-d0cb-4fb3-9b9e-983475779eda"},"_deposit":{"created_by":1,"id":"71750","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"71750"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00071750","sets":["10:28"]},"author_link":["706211","706216","706220","706212","706214","706218","706222","706223","706225","706213","706208","706209","706224","706221","706217","706215","706219","706210"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2014-09-17","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"For quality assurance (QA) of therapeutic ion beams, QA tool having high spatial resolution and quick verification is required. The imaging system with a fluorescent screen is suitable for QA procedure. We developed a quick verification system (NQA-SCN) using a fluorescent screen with a charge-coupled device (CCD) camera for the sake of two dimensional dosimetry. In carbon-ion therapy, the fluorescent light is decreased by suffering from quenching effect due to the increased linear energy transfer (LET) in the Bragg peak. For the use of three-dimensional dose verification, we performed a simple correction for quenching effect and several types of corrections for the optical artifact. In addition, NQA-SCN is attached with an accordion-type water phantom which makes it possible to easily change measurement depth. To evaluate the performance of NQA-SCN, we carried out experiments concerning QA procedures. In my presentation, we provide correction methods and detailed analysis of measured results.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"The 3rd International Beam Instrumentation Coference (IBIC2014)","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hara, Yousuke"}],"nameIdentifiers":[{"nameIdentifier":"706208","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Furukawa, Takuji"}],"nameIdentifiers":[{"nameIdentifier":"706209","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mizushima, Kota"}],"nameIdentifiers":[{"nameIdentifier":"706210","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Noda, Koji"}],"nameIdentifiers":[{"nameIdentifier":"706211","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Saotome, Naoya"}],"nameIdentifiers":[{"nameIdentifier":"706212","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shirai, Toshiyuki"}],"nameIdentifiers":[{"nameIdentifier":"706213","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takeshita, Eri"}],"nameIdentifiers":[{"nameIdentifier":"706214","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tansho, Ryohei"}],"nameIdentifiers":[{"nameIdentifier":"706215","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Saraya, Yuichi"}],"nameIdentifiers":[{"nameIdentifier":"706216","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"原 洋介","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"706217","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"古川 卓司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"706218","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"水島 康太","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"706219","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田 耕司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"706220","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"早乙女 直也","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"706221","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白井 敏之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"706222","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"竹下 英里","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"706223","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"丹正 亮平","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"706224","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"皿谷 有一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"706225","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Development of three-dimensional dose verification system using a fluorescent screen in ion beam therapy","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development of three-dimensional dose verification system using a fluorescent screen in ion beam therapy"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-06-30"},"publish_date":"2015-06-30","publish_status":"0","recid":"71750","relation_version_is_last":true,"title":["Development of three-dimensional dose verification system using a fluorescent screen in ion beam therapy"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:47:49.230954+00:00"}