{"created":"2023-05-15T14:52:26.507372+00:00","id":71600,"links":{},"metadata":{"_buckets":{"deposit":"df3fec46-0b42-4b8d-8d89-2ae73261054e"},"_deposit":{"created_by":1,"id":"71600","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"71600"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00071600","sets":["10:28"]},"author_link":["704209","704207","704211","704210","704214","704212","704213","704208","704215","704219","704220","704218","704217","704221","704206","704216"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2015-03-10","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"病院内でPET薬剤を製造する際、「無菌性の確保」が大きな課題となる。その達成のためには、(1)更衣等の手間やコストの増大、無菌操作技術の習得に起因する無菌性を確保することの困難さ、(2)(1)の結果として生じる作業効率及び精度の低下、等の克服が必要となる。標準化推進・品質保証室及び分子認識研究PGは、この度この2つの課題を同時に克服し、より高次元の無菌性確保を可能とする装置(PET薬剤製剤化用無菌アイソレータ)を協力企業と共に開発した。この装置は給排気HEPAユニット、陽圧設定高気密装置、過酸化水素による除染装置から成り、微生物から庫内を完全に分離した環境下で作業者はグローブを通して作業を行う。特に最終製剤化の工程は、遮蔽体に覆われた自動分注器により、被曝することなく行われる。この装置により、放医研のみならず世界のPET薬剤製造施設で、医薬品レベルの高い無菌性保証が可能になると期待される。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第9回技術と安全の報告会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"脇, 厚生"}],"nameIdentifiers":[{"nameIdentifier":"704206","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金子, いづみ"}],"nameIdentifiers":[{"nameIdentifier":"704207","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"岩隈, 佳寿子"}],"nameIdentifiers":[{"nameIdentifier":"704208","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"河村, 和紀"}],"nameIdentifiers":[{"nameIdentifier":"704209","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木, 寿"}],"nameIdentifiers":[{"nameIdentifier":"704210","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"橋本, 裕輝"}],"nameIdentifiers":[{"nameIdentifier":"704211","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"張, 明栄"}],"nameIdentifiers":[{"nameIdentifier":"704212","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"藤林, 康久"}],"nameIdentifiers":[{"nameIdentifier":"704213","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"脇 厚生","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"704214","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金子 いづみ","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"704215","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"岩隈 佳寿子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"704216","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"河村 和紀","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"704217","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木 寿","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"704218","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"橋本 裕輝","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"704219","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"張 明栄","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"704220","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"藤林 康久","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"704221","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"世界初PET薬剤製剤化用無菌アイソレータの開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"世界初PET薬剤製剤化用無菌アイソレータの開発"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-03-24"},"publish_date":"2015-03-24","publish_status":"0","recid":"71600","relation_version_is_last":true,"title":["世界初PET薬剤製剤化用無菌アイソレータの開発"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:49:26.336647+00:00"}