{"created":"2023-05-15T14:52:20.152850+00:00","id":71455,"links":{},"metadata":{"_buckets":{"deposit":"f3375cdd-ce67-43b5-ae8c-d89239fb3a85"},"_deposit":{"created_by":1,"id":"71455","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"71455"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00071455","sets":["10:28"]},"author_link":["702565","702570","702563","702564","702567","702568","702571","702566","702569","702573","702574","702572"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2014-05-23","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"【目的】小動物用SPECT/PET/CT装置VECTorは、陽電子からの高エネルギーの消滅放射線に対してペネトレーションを抑制する工夫のされたポジトロン用clustered-multipinholeコリメータを装備し、SPECTとPETの2核種同時収集が可能とされる。本コリメータの99mTcと18Fに対する基本性能を評価した。\n\\n【方法】2種類のロッドファントムを用いて空間分解能を評価した。100μL点線源を用いて感度、計数率特性を測定した。また、2核種同時収集時の18Fから99mTc画像へのspill-overを評価するために、2つの点状線源(99mTcのみ、99mTc +18Fの混合)を用いて放射能濃度比(18F/99mTc)に対するSPECTカウント比(99mTc/99mTc+18F)を算出した。\n\\n【結果】99mTcは直径0.5mm、18Fは0.8mmロッドを弁別可能であった。感度は0.28%(99mTc)、0.29%(18F)と高い値を示した。計数率のピークは588kcps(99mTc)、264kcps(18F)で、共に120kcps程度まで放射能濃度に対する直線性が優れていた。消滅放射線によるペネトレーションにより、170keV付近に光子ピークを形成し、99mTc画像に影響を与える。18F/99mTc放射能濃度比が2以下で、SPECTカウント比はほぼ1を示した。つまり、18Fの放射能量が99mTcに対して2倍以下の場合、spill-overの影響をほとんど無視できる。\n\\n【結語】VECTorにより撮像したSPECTとPETは、高分解能と高感度を両立していた。99mTcと18Fの放射能量を調整することにより、2核種同時収集も充分に実用範囲内である。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第9回日本分子イメージング学会総会・学術集会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"三輪, 建太"}],"nameIdentifiers":[{"nameIdentifier":"702563","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"犬伏, 正幸"}],"nameIdentifiers":[{"nameIdentifier":"702564","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"竹内, 康人"}],"nameIdentifiers":[{"nameIdentifier":"702565","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"片渕, 哲朗"}],"nameIdentifiers":[{"nameIdentifier":"702566","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小泉, 満"}],"nameIdentifiers":[{"nameIdentifier":"702567","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐々木, 雅之"}],"nameIdentifiers":[{"nameIdentifier":"702568","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐賀, 恒夫"}],"nameIdentifiers":[{"nameIdentifier":"702569","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"三輪 建太","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"702570","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"犬伏 正幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"702571","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"竹内 康人","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"702572","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小泉 満","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"702573","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐賀 恒夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"702574","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"小動物用SPECT/PET装置を用いた99mTc/18F同時収集法の基礎的検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"小動物用SPECT/PET装置を用いた99mTc/18F同時収集法の基礎的検討"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-05-30"},"publish_date":"2014-05-30","publish_status":"0","recid":"71455","relation_version_is_last":true,"title":["小動物用SPECT/PET装置を用いた99mTc/18F同時収集法の基礎的検討"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:51:04.139057+00:00"}