{"created":"2023-05-15T14:52:06.017826+00:00","id":71185,"links":{},"metadata":{"_buckets":{"deposit":"b1e7c299-bb14-48a5-8074-fc3ec2b27621"},"_deposit":{"created_by":1,"id":"71185","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"71185"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00071185","sets":["10:28"]},"author_link":["699827","699824","699826","699828","699831","699825","699830","699829"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2013-07-06","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"放射線医学総合研究所内の低線量影響実験棟に設置されている中性子線照射装置(NASBEE)は、主に2MVのタンデム加速器からの重水素ビームをベリリウムターゲットに照射することで、発生した中性子を利用する装置である。平成15年度に導入されて以来、所内外の多くの研究者に利用されている。昨年夏にタンデム加速器の荷電変換ガス圧が不安定になる現象が起きた。コントロール系統を調べたが異常は見つからず、結局加速器を開けて点検することになった。今回は昨年度の運転状況と突然問題が発生した加速器の荷電変換ガスのトラブルについて報告する。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第26回タンデム加速器及びその周辺技術の研究会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"酢屋, 徳啓"}],"nameIdentifiers":[{"nameIdentifier":"699824","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"須田, 充"}],"nameIdentifiers":[{"nameIdentifier":"699825","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"萩原, 拓也"}],"nameIdentifiers":[{"nameIdentifier":"699826","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白川, 芳幸"}],"nameIdentifiers":[{"nameIdentifier":"699827","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"酢屋 徳啓","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"699828","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"須田 充","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"699829","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"萩原 拓也","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"699830","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白川 芳幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"699831","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"放医研中性子線照射装置(NASBEE)の現状","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"放医研中性子線照射装置(NASBEE)の現状"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-07-08"},"publish_date":"2013-07-08","publish_status":"0","recid":"71185","relation_version_is_last":true,"title":["放医研中性子線照射装置(NASBEE)の現状"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:54:13.348166+00:00"}