{"created":"2023-05-15T14:51:59.914719+00:00","id":71082,"links":{},"metadata":{"_buckets":{"deposit":"f842f90e-ad3f-4ba6-8ae9-f28a41af8c4c"},"_deposit":{"created_by":1,"id":"71082","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"71082"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00071082","sets":["10:28"]},"author_link":["698669","698674","698668","698675","698677","698678","698663","698672","698670","698671","698662","698661","698667","698666","698676","698664","698665","698673"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2013-04-14","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"【背景・目的】硬さと剪断弾性波伝搬速度 (Vs) の関係を利用して,超音波装置を用いた組織弾性の定量評価 (VTTQ: Virtual Touch Tissue Quantification) が可能となったが,その再現性や数値の信頼性に関する検証は少ない.今回われわれは9MHzリニアプローベを用いて頚部リンパ節のVTTQを行った場合の信頼性や測定のばらつきを検討した.【方法】2011年2月から2012年9月までに頚部超音波検査を行いリンパ節のVTTQを測定した51例中,同一リンパ節に対して3回以上の測定を行った35例83結節を対象とした.装置はAcuson S2000で,9MHzリニアプローベを用いた.3回の測定における信頼性の評価には級内相関係数 (ICC) を計算し,またリンパ節の長径・短径・深さ・平均Vsと変動係数CV(標準偏差/平均)との相関係数(Pearsonの積率相関係数)を求めた.統計解析にはSPSSを用いた.【結果】ICCは単一測定値が0.63,3回の平均測定値が0.84と,3回測定では信頼性が高かったが,0.9以上のICCを得るためには6回の測定が必要と計算された.リンパ節の長径や平均VsとCVには有意な相関はなかったが (r=0.12, -0.15),短径とは負の相関 (r=-0.5),深さとは正の相関 (r=0.69) があった.【結論】9MHzリニアプローベを用いて頚部リンパ節のVTTQを行う場合,高い信頼性を得るためには最低でも3回以上の測定を行いその平均を求める必要があった.また短径の小さいリンパ節,深い位置にあるリンパ節ほど測定のばらつきが大きく,信頼性を高めるためには,更に測定回数を増やす必要があると考えられた.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第72回日本医学放射線学会総会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"岸本, 理和"}],"nameIdentifiers":[{"nameIdentifier":"698661","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"立花, 泰彦"}],"nameIdentifiers":[{"nameIdentifier":"698662","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"尾松, 徳彦"}],"nameIdentifiers":[{"nameIdentifier":"698663","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小畠, 隆行"}],"nameIdentifiers":[{"nameIdentifier":"698664","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小藤, 昌志"}],"nameIdentifiers":[{"nameIdentifier":"698665","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"長谷川, 安都佐"}],"nameIdentifiers":[{"nameIdentifier":"698666","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高木, 亮"}],"nameIdentifiers":[{"nameIdentifier":"698667","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"神立, 進"}],"nameIdentifiers":[{"nameIdentifier":"698668","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鎌田, 正"}],"nameIdentifiers":[{"nameIdentifier":"698669","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"岸本 理和","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"698670","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"立花 泰彦","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"698671","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"尾松 徳彦","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"698672","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小畠 隆行","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"698673","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小藤 昌志","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"698674","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"長谷川 安都佐","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"698675","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高木 亮","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"698676","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"神立 進","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"698677","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鎌田 正","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"698678","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"超音波を用いた組織弾性定量測定の信頼性の検討ー頚部リンパ節の測定","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"超音波を用いた組織弾性定量測定の信頼性の検討ー頚部リンパ節の測定"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-04-23"},"publish_date":"2013-04-23","publish_status":"0","recid":"71082","relation_version_is_last":true,"title":["超音波を用いた組織弾性定量測定の信頼性の検討ー頚部リンパ節の測定"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:55:24.196368+00:00"}