{"created":"2023-05-15T14:51:58.876786+00:00","id":71058,"links":{},"metadata":{"_buckets":{"deposit":"2df3aa0a-ccdd-49cf-90cd-d61dba8f233f"},"_deposit":{"created_by":1,"id":"71058","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"71058"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00071058","sets":["10:28"]},"author_link":["698416","698423","698429","698419","698428","698417","698425","698427","698421","698418","698422","698424","698420","698414","698415","698426"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2012-09-15","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"発表概略:\nCT検査における被ばく線量低減法は、昨今様々な機器や器具を使用した工夫がなされている。\n今発表は、ヘリカルスキャンのピッチ及びビーム幅の制御を適切に行うことで、特別に機器を投入することなく、簡便に体表面臓器の被ばく低減を実現可能であるとの測定結果と、次世代の被ばく低減機構としての可能性を示唆した。尚、体表面臓器を仮定したCTヘリカルスキャン様態を反映した「体深部吸収線量」連続分布の実測結果(PMMAファントム内ではあるが)を示すのは、本研究が初である。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第104回日本医学物理学会学術大会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"小原, 哲"}],"nameIdentifiers":[{"nameIdentifier":"698414","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"青天目, 州晶"}],"nameIdentifiers":[{"nameIdentifier":"698415","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"盧, 暁光"}],"nameIdentifiers":[{"nameIdentifier":"698416","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鶴岡, 伊知郎"}],"nameIdentifiers":[{"nameIdentifier":"698417","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"斉藤, 収三"}],"nameIdentifiers":[{"nameIdentifier":"698418","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"赤羽, 恵一"}],"nameIdentifiers":[{"nameIdentifier":"698419","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"島田, 義也"}],"nameIdentifiers":[{"nameIdentifier":"698420","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮嵜, 治"}],"nameIdentifiers":[{"nameIdentifier":"698421","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小原 哲","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"698422","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"青天目 州晶","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"698423","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"盧 暁光","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"698424","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鶴岡 伊知郎","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"698425","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"斉藤 収三","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"698426","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"赤羽 恵一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"698427","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"島田 義也","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"698428","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮嵜 治","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"698429","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"患者被ばく線量の低減―ヘリカルCTにおけるスキャンピッチ制御","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"患者被ばく線量の低減―ヘリカルCTにおけるスキャンピッチ制御"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-03-06"},"publish_date":"2013-03-06","publish_status":"0","recid":"71058","relation_version_is_last":true,"title":["患者被ばく線量の低減―ヘリカルCTにおけるスキャンピッチ制御"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:55:41.377410+00:00"}