{"created":"2023-05-15T14:51:55.564071+00:00","id":70982,"links":{},"metadata":{"_buckets":{"deposit":"0d840658-cab5-45bd-ad3f-3e4ecd76c4ab"},"_deposit":{"created_by":1,"id":"70982","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"70982"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00070982","sets":["10:28"]},"author_link":["697703","697693","697686","697688","697691","697696","697690","697687","697698","697701","697702","697697","697692","697695","697700","697694","697689","697699"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2012-11-03","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"One of the challenging applications of PET is implementing it for in-beam PET, which is an in situ monitoring method for charged particle therapy. For this purpose, we have previously proposed an open-type PET scanner, OpenPET. The original OpenPET had a physically opened field of view (FOV) between two detector rings through which irradiation beams pass. This dual-ring OpenPET (DROP) had a wide axial FOV including the gap. This geometry was not necessarily the most efficient for application to in-beam PET in which only a limited FOV around the irradiation field is required. Therefore, we have proposed a new single-ring OpenPET (SROP) geometry which can provide an accessible and observable open space with higher sensitivity and a reduced number of detectors than the DROP. The proposed geometry was a cylinder shape with its ends cut at a slant, in which the shape of each cut end became an ellipse. In this work, we developed and evaluated a small prototype of the SROP geometry for proof-of-concept. The SROP prototype was designed with 2 ellipse-shaped detector rings of 16 DOI detectors. The DOI detectors consisted of 1024 GSOZ crystals which were arranged in 4 layers of 16 X 16 arrays, coupled to a 64-ch FP-PMT. Each ellipse-shaped detector ring had a major axis of 281.6 mm and a minor axis of 207.5 mm. For the open mode, the rings were placed at a 45-deg slant from the axial direction and for the non-open mode (used as a reference) they were at 90 deg from the axial direction with no gap. The system sensitivity and average spatial resolution were measured from a 22Na point source and were 5.0 % and 2.7 mm, respectively, for the open mode. Comparison between the open mode and the non-open mode showed no remarkable difference in terms of the sensitivity distribution and spatial resolution performance. Therefore, we concluded that the SROP geometry has a good potential as an open geometry especially suitable for in-beam imaging.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"2012IEEE NSS&MIC","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Yoshida, Eiji"}],"nameIdentifiers":[{"nameIdentifier":"697686","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kinouchi, Shoko"}],"nameIdentifiers":[{"nameIdentifier":"697687","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tashima, Hideaki"}],"nameIdentifiers":[{"nameIdentifier":"697688","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nishikido, Fumihiko"}],"nameIdentifiers":[{"nameIdentifier":"697689","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hirano, Yoshiyuki"}],"nameIdentifiers":[{"nameIdentifier":"697690","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Inadama, Naoko"}],"nameIdentifiers":[{"nameIdentifier":"697691","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Murayama, Hideo"}],"nameIdentifiers":[{"nameIdentifier":"697692","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ito, Hiroshi"}],"nameIdentifiers":[{"nameIdentifier":"697693","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamaya, Taiga"}],"nameIdentifiers":[{"nameIdentifier":"697694","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"吉田 英治","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697695","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"木内 尚子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697696","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田島 英朗","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697697","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"錦戸 文彦","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697698","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"平野 祥之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697699","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"稲玉 直子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697700","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"村山 秀雄","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697701","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"伊藤 浩","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697702","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山谷 泰賀","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697703","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Development and performance evaluation of a single-ring OpenPET prototype","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development and performance evaluation of a single-ring OpenPET prototype"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-11-16"},"publish_date":"2012-11-16","publish_status":"0","recid":"70982","relation_version_is_last":true,"title":["Development and performance evaluation of a single-ring OpenPET prototype"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:56:33.985078+00:00"}