{"created":"2023-05-15T14:51:55.477898+00:00","id":70980,"links":{},"metadata":{"_buckets":{"deposit":"6990a9a0-435d-45f3-ad18-55a86dabf09e"},"_deposit":{"created_by":1,"id":"70980","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"70980"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00070980","sets":["10:28"]},"author_link":["697654","697665","697657","697663","697661","697655","697664","697653","697652","697659","697656","697662","697660","697658"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2012-11-09","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Two-dimensional dosimetry system was developed for quality assurance (QA) of therapeutic scanned ion beams at HIMAC. This system consists of a fluorescent screen and a charge coupled device (CCD) camera. To evaluate the performance of this system, we carried out a few experiments for QA procedures. The verification of this system was also carried out by comparing the film dosimetry and the ionization chamber array. Also, we verified several types of corrections about errors, e.g. background, vignetting, to distort the measurement results. As a result, we confirmed that this system could be used as the system for QA procedures of therapeutic scanned ion beams.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"The 16th International Conference on Accelerators and Beam Utilizations","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hara, Yousuke"}],"nameIdentifiers":[{"nameIdentifier":"697652","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Furukawa, Takuji"}],"nameIdentifiers":[{"nameIdentifier":"697653","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takeshita, Eri"}],"nameIdentifiers":[{"nameIdentifier":"697654","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mizushima, Kota"}],"nameIdentifiers":[{"nameIdentifier":"697655","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Satou, Shinji"}],"nameIdentifiers":[{"nameIdentifier":"697656","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shirai, Toshiyuki"}],"nameIdentifiers":[{"nameIdentifier":"697657","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Noda, Kouji"}],"nameIdentifiers":[{"nameIdentifier":"697658","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"原 洋介","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697659","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"古川 卓司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697660","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"竹下 英里","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697661","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"水島 康太","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697662","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐藤 眞二","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697663","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白井 敏之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697664","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田 耕司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697665","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Performance of a Fluorescent Screen with a CCD System for Quality Assurance in Heavy-ion Beam Scanning Irradiation System","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Performance of a Fluorescent Screen with a CCD System for Quality Assurance in Heavy-ion Beam Scanning Irradiation System"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-11-14"},"publish_date":"2012-11-14","publish_status":"0","recid":"70980","relation_version_is_last":true,"title":["Performance of a Fluorescent Screen with a CCD System for Quality Assurance in Heavy-ion Beam Scanning Irradiation System"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:56:35.382676+00:00"}