{"created":"2023-05-15T14:51:54.837845+00:00","id":70966,"links":{},"metadata":{"_buckets":{"deposit":"44f1f149-5603-463b-ad3e-97c3df17f125"},"_deposit":{"created_by":1,"id":"70966","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"70966"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00070966","sets":["10:28"]},"author_link":["697456","697460","697455","697457","697459","697461","697462","697458"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2012-10-21","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Hypoxia is one of the most common causes for tumor radioresistance and metastasis. High LET irradiation is expected to reduce these problems. However, although the dependence of the oxygen enhancement ratio (OER) from LET has been previously measured at the Lawrence Berkeley Laboratory (USA) and HIMAC (Japan), no data are available for intermediate oxygen concentrations, especially between 0.1% and 2%, where the OER sharply increases after X-rays.\nHere we report the first measurements of the OER and relative biological effectiveness (RBE), for different LET, ions (carbon, nitrogen, oxygen and lithium) at different oxygen concentrations: normoxic (air), hypoxic (0.5%O2) and anoxic (0% O2).\nThe carbon irradiation gave an OER value of 1.8+/-0.1 in anoxia, while for photon irradiation it results in a value of 2.4+/-0.1. In hypoxia, the OER values decrease to 1.29+/-0.07 and to 1.5+/-0.1 for carbon and photon irradiation respectively.\nOER values decrease with increasing LET. The values found were from 1.8+/-0.1 for carbon 100 keV/mm to 1.30+/-0.04 for nitrogen 160 keV/mm. A clear influence of atomic number could not be seen in this atomic number range.\nAbout the RBE results, in anoxia the RBE value increases with increasing LET. The range of values found was from 3.1+/-0.2 for carbon 100 keV/mm to 4.4+/-0.2 for nitrogen 160 keV/mm while does not change in normoxic condition: 2.6+/-0.2 to 2.4+/-0.2. \nExperiments to measure the full OER-LET curves at intermediate oxygen concentrations at HIMAC within the program of the IOL \"Radiation Quality\".","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"The 10th International Symposium on Chromosomal Aberrations","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Tinganelli, Walter"}],"nameIdentifiers":[{"nameIdentifier":"697455","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Durante, Marco"}],"nameIdentifiers":[{"nameIdentifier":"697456","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hirayama, Ryoichi"}],"nameIdentifiers":[{"nameIdentifier":"697457","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Furusawa, Yoshiya"}],"nameIdentifiers":[{"nameIdentifier":"697458","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"et.al"}],"nameIdentifiers":[{"nameIdentifier":"697459","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"ティンガネリ ワルター","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697460","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"平山 亮一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697461","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"古澤 佳也","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697462","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Oxygen enhancement ratio measured for heavy ions at different LET in various oxygen concentrations","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Oxygen enhancement ratio measured for heavy ions at different LET in various oxygen concentrations"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-11-07"},"publish_date":"2012-11-07","publish_status":"0","recid":"70966","relation_version_is_last":true,"title":["Oxygen enhancement ratio measured for heavy ions at different LET in various oxygen concentrations"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:56:45.262174+00:00"}