{"created":"2023-05-15T14:51:53.629832+00:00","id":70939,"links":{},"metadata":{"_buckets":{"deposit":"da508194-aada-4791-9b2b-0a281487fd01"},"_deposit":{"created_by":1,"id":"70939","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"70939"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00070939","sets":["10:28"]},"author_link":["697091","697092","697085","697084","697090","697087","697083","697086","697088","697089"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2012-10-13","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":" 【目的】近年、麻酔による生理状態への影響を避ける為に、覚醒状態の動物でのPET測定技術が開発されている。本研究では、PET計測中の自発行動が可能なPETおよび動物歩行量の同時測定実験系を構築した。【方法】PET内に設置された自家製歩行測定装置にマウスを固定した。マウスの直下には、空気流により浮遊した発泡スチロール製の玉があり、マウスの運動時に足の動きに連動して回転する。この玉の動きをセンサーで検出し、球の回転量から歩行量を計算した。また、FDGによるダイナミックPETスキャンを同時に行った。【結果と考察】PETスキャン開始前10分間とスキャン中の平均歩行速度は、2.1 mm/secであった(n=3)。PETスキャン中の平均歩行速度(1.8 mm/sec)は、スキャン開始前の平均歩行速度(2.8 mm/sec)よりも小さかったが、FDG静注に伴う歩行速度の明らかな変化は見られなかった。FDG-PETの画像に、自発歩行に由来するアーチファクトは見られなかった。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第 52 回日本核医学会学術総会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"田桑, 弘之"}],"nameIdentifiers":[{"nameIdentifier":"697083","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"脇坂, 秀克"}],"nameIdentifiers":[{"nameIdentifier":"697084","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"関, 千江"}],"nameIdentifiers":[{"nameIdentifier":"697085","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"菅野, 巖"}],"nameIdentifiers":[{"nameIdentifier":"697086","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"伊藤, 浩"}],"nameIdentifiers":[{"nameIdentifier":"697087","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田桑 弘之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697088","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"脇坂 秀克","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697089","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"関 千江","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697090","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"菅野 巖","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697091","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"伊藤 浩","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"697092","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"覚醒マウスにおけるFDG-PETと自発運動量の同時計測実験系の構築","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"覚醒マウスにおけるFDG-PETと自発運動量の同時計測実験系の構築"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-10-17"},"publish_date":"2012-10-17","publish_status":"0","recid":"70939","relation_version_is_last":true,"title":["覚醒マウスにおけるFDG-PETと自発運動量の同時計測実験系の構築"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:57:05.038876+00:00"}