{"created":"2023-05-15T14:51:22.692961+00:00","id":70237,"links":{},"metadata":{"_buckets":{"deposit":"ab14247d-a093-4324-9fb7-5adf52d8fe18"},"_deposit":{"created_by":1,"id":"70237","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"70237"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00070237","sets":["10:28"]},"author_link":["689678","689677","689685","689687","689689","689681","689680","689688","689683","689690","689682","689684","689686","689679"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2010-09-11","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"It has long been hypothesised that restricted (or hindered) motion of water molecules is responsible for the anisotropic image contrast in diffusion-tensor MRI, in particular in white matter. It has also been recognised that in that case, by varying the length or separation of the motion-probing gradients (MPGs), it should be possible to alter the contrast of in vivo images and thus common measures of diffusion anisotropy to probe tissue microstructure. Most previous efforts were unable to find in vivo evidence for the restricted-diffusion hypothesis (eg Clark1), but recent work using a technique that utilises rapidly oscillating MPGs added to a standard spin-echo sequence, has demonstrated some of the characteristics of restricted diffusion for in vitro samples, and normal and diseased rat brain2-4. However, the technique has never been applied to examine alterations to apparent diffusion anisotropy as the MPG frequency is increased (or, equivalently, the diffusion-time is decreased). In this study, an oscillating MPG sequence was applied to investigate changes to the apparent diffusion tensor, fractional anisotropy and mean diffusivity in rat cerebellum. The gradient frequencies were in the range 30-200 Hz and corresponded to effective diffusion times of 1-8 ms2.\nThe results clearly showed that the mean diffusivity increased with MPG frequency, which is a characteristic expected of the restricted/hindered diffusion model (see figure below). Other indices of diffusion anisotropy were also visibly altered by changes to the MPG frequency.\n Given sufficient gradient-set performance, it is anticipated that normal and pathological in vivo tissue structure can be probed with this technique to frequencies of at least 1-2 kHz.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"World Molecular Imaging Congress 2010","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kershaw, Jeffrey"}],"nameIdentifiers":[{"nameIdentifier":"689677","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Leuze, Christoph"}],"nameIdentifiers":[{"nameIdentifier":"689678","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Joonas, Autio"}],"nameIdentifiers":[{"nameIdentifier":"689679","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shibata, Sayaka"}],"nameIdentifiers":[{"nameIdentifier":"689680","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Obata, Takayuki"}],"nameIdentifiers":[{"nameIdentifier":"689681","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanno, Iwao"}],"nameIdentifiers":[{"nameIdentifier":"689682","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Aoki, Ichio"}],"nameIdentifiers":[{"nameIdentifier":"689683","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kershaw Jeffrey","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689684","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"ロイツェ クリストフ","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689685","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"ヨーナス オーティオ","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689686","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"柴田 さやか","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689687","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小畠 隆行","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689688","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"菅野 巖","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689689","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"青木 伊知男","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689690","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Apparent diffusion anisotropy in rat cerebellum is altered at short effective diffusion-times using oscillating-gradient diffusion-tensor MRI","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Apparent diffusion anisotropy in rat cerebellum is altered at short effective diffusion-times using oscillating-gradient diffusion-tensor MRI"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2010-09-14"},"publish_date":"2010-09-14","publish_status":"0","recid":"70237","relation_version_is_last":true,"title":["Apparent diffusion anisotropy in rat cerebellum is altered at short effective diffusion-times using oscillating-gradient diffusion-tensor MRI"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:05:17.342530+00:00"}