{"created":"2023-05-15T14:51:20.979151+00:00","id":70198,"links":{},"metadata":{"_buckets":{"deposit":"3d24bee3-a74b-4d64-a641-af2608abdfc3"},"_deposit":{"created_by":1,"id":"70198","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"70198"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00070198","sets":["10:28"]},"author_link":["689354","689357","689365","689366","689353","689358","689360","689362","689364","689359","689355","689361","689363","689367","689356","689368"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2010-03-17","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"PIXE分析法は、少ない試料でも繰り返し測定でき、定量可能な多元素同時分析法ということから、近年、多くの研究・教育機関でエアロゾル、水生生物などの環境試料の解析に利用されている。しかし、定量のためには、イオンビーム照射量を正確に知ることが重要であるが、真空中に試料をおくPIXE分析法では、試料によって厚みや状態が異なるので、ターゲットとなる試料の電流積算値が照射量に比例するとは限らない。そのため、PIXE分析において試料の状態に依らず、照射量を正確に制御できるリアルタイムビームモニタの開発を行ってきた。\n本報告会では、現在までに開発してきたコンベンショナルPIXEのリアルタイムビームモニタの現状について報告する。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第5回技術と安全の報告会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"石川, 剛弘"}],"nameIdentifiers":[{"nameIdentifier":"689353","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"及川, 将一"}],"nameIdentifiers":[{"nameIdentifier":"689354","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"磯, 浩之"}],"nameIdentifiers":[{"nameIdentifier":"689355","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"酢屋, 徳啓"}],"nameIdentifiers":[{"nameIdentifier":"689356","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小西, 輝昭"}],"nameIdentifiers":[{"nameIdentifier":"689357","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"樋口, 有一"}],"nameIdentifiers":[{"nameIdentifier":"689358","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北村, 尚"}],"nameIdentifiers":[{"nameIdentifier":"689359","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関, 等"}],"nameIdentifiers":[{"nameIdentifier":"689360","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川 剛弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689361","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"及川 将一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689362","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"磯 浩之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689363","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"酢屋 徳啓","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689364","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小西 輝昭","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689365","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"樋口 有一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689366","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北村 尚","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689367","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関 等","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"689368","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"PIXE用リアルタイムビームモニタ開発の現状","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"PIXE用リアルタイムビームモニタ開発の現状"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2010-08-04"},"publish_date":"2010-08-04","publish_status":"0","recid":"70198","relation_version_is_last":true,"title":["PIXE用リアルタイムビームモニタ開発の現状"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:05:43.986112+00:00"}