{"created":"2023-05-15T14:51:18.629052+00:00","id":70144,"links":{},"metadata":{"_buckets":{"deposit":"365b59cf-619c-43f9-bed0-4052456f3941"},"_deposit":{"created_by":1,"id":"70144","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"70144"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00070144","sets":["10:28"]},"author_link":["688775","688776"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2010-05-28","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The development of the screen monitor system (SCN) at the Heavy Ion Medical Accelerator in Chiba (HIMAC) comprises the surveillance of the carbon beam. In the three-dimensional scanning system for the carbon therapy, the beam qualities, i.e., position, size and intensity of the beam, play a significant role for the patient's treatment. Therefore, we designed a semi-nondestructive monitoring system located on the high-energy beam transport line to monitor the beam qualities by using a thin fluorescent screen and a high-speed charge-coupled device. The beam position and profile were obtained from the light emitting distribution of the screen.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"The 1st International Particle Accelerator Conference","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Takeshita, Eri"}],"nameIdentifiers":[{"nameIdentifier":"688775","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"竹下 英里","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"688776","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Semi-nondestructive monitoring system for high-energy beam","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Semi-nondestructive monitoring system for high-energy beam"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2010-06-04"},"publish_date":"2010-06-04","publish_status":"0","recid":"70144","relation_version_is_last":true,"title":["Semi-nondestructive monitoring system for high-energy beam"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:06:20.548679+00:00"}